background image

Fremont Outswing Opener

Installation Manual

Содержание Fremont Outswing Opener

Страница 1: ...Fremont Outswing Opener Installation Manual ...

Страница 2: ...ements It is also a good idea to install a surge protector to avoid any damage to the operator The operator can be damaged by power surges or faulty wiring CAUTION All California residents must have a battery backup installed with electronic door openers according to Senate Bill No 969 Please call our main line for assistance or check out our website for additional information Thank you for choosi...

Страница 3: ...itting 16 Header Brackets 17 Push Rods 18 Mounting Control Unit 19 Inserting ACCU battery backup 20 Photo Eyes 21 Autoset Programming 22 Red Limit Stop 22 Autoset 23 After Autoset Completion 24 Battery Pack ACCU Installation 24 Adjusting the Close Limit 24 Troubleshooting 24 Accessories 25 Remotes 25 Homelink 25 Battery Pack 26 MEMO 26 SOMLINK 26 SOMweb 27 SENSO 27 Outdoor Keypad 27 Wireless Wall ...

Страница 4: ...track pieces 4 Chain tensioner for closing end of track 5 Wire Connector open end of track 5 1 Ceiling bracket which is 2 parts 6 Ceiling bracket hardware 7 2 bolts M8 x 20 wrench size with two self locking nuts M8 8 Door Arm 9 Note not needed for Fremont application Curved door arm 10 Note not needed for Fremont application Header bracket with pin and 2 locking c clips 11 2 screws 8 x 60mm wrench...

Страница 5: ...packaged in a tube with the dimensions 95 x 2 x 2 Note The length will increase based on your opening size and may be shipped freight Additional Parts Box This box includes additional items needed for your swing out application The package dimensions are 15 x 12 x 3 This box will include Secondary remote for your convenience Keep this remote separate from the one included in the main box This remo...

Страница 6: ...al Troubleshooting page 62 Warranty information page 67 Ceiling mounting and position page 24 Technical Data 2060 pro 2080 pro 2110 pro Rated voltage 24V DC Rated frequency 60 Hz Number of programma ble remote buttons 40 Duty cycle 40 Emission value according to operating environment 59 dBA opener only IP code NEMA1 IP21 Protection class class 2 Standard door height 7 and 8 doors 2 750 mm Max door...

Страница 7: ...opening active Illumination function 3 Side opening sectional door Sectional door 4 Retractable door Sectional door Reset Button The length of time the reset button is pressed will define what is reset see below options 1 2 seconds will reset the safety devices 5 seconds the force values will be deleted 10 seconds the end position or close will be deleted 30 seconds will be full factory reset ...

Страница 8: ...mit switch terminal OPEN limit blue 4 PCB label 5 LEDs opener lighting 6 MEMO slot MEMO terminal 7 USART slot interface 8 BUZZER slot black Warning or alarm buzzer terminal 9 SENSO slot SENSO terminal 10 LASER slot white Parking position laser sensor terminal 11 Terminal for safety contact strip 8k2 OSE 12 Terminal for wicket door contact potential free 13 Status LED green 14 Reset button green 15...

Страница 9: ...0 transmitter commands USART slot terminal e g module home automation SENSO slot terminal for SENSO humidity sensor BUZZER slot black terminal for warning alarm buzzer LASER slot white terminal for parking position sensor Safety contact strip 8k2 terminal OSE safety contact strip terminal 12V br OSE gn GND wh Wicket door fuse terminal contact command 12V 10mA normally closed contact potential free...

Страница 10: ...for button connector cable of the wall control unit 4 Terminal for relay 5 2 pin Terminal power supply 120 V AC 50 60 hz 6 2 pin Terminal Transformer primary side 120 V AC 50 60 Hz 7 2 pin Terminal 24 V AC Transformer secondary side 8 PCB label 9 2 pin Terminal Chain and Track 24 V AC 10 Light slot white Terminal for Lumi supplementary lighting 11 2 pin Terminal Safety Sensors 12 2 pin Terminal wa...

Страница 11: ...ot white Terminal for Lumi supplementary lighting 2 pin Terminal Safety Sensors any polarity 2 pin Terminal wall station or wall button potential free Deinstalling the Control Unit Cover 1 Disconnect the opener from the main power supply 2 Loosen the screw on the control unit cover and remove the cover gently upwards 3 Unplug the connection cable for the membrane keypad from the wall control unit ...

Страница 12: ...must be located on the door side of the rail open end The control unit housing must be mounted at least 5ft from the ground within 16 4ft of the open end of the rail and no more than 5 7ft 69 from an outlet These distances cannot be extended The wire connector is positioned on the open end of the track nearest the doors and is wired to the control unit housing This will supply power to the rail Pu...

Страница 13: ... 5 7 from an outlet The wire connector chord is 16ft long Direct mounting brackets provided Additional mounting hardware will need to be sourced for drop down applications as shown in picture and is not provided Control unit has an operation light and vacation button located on front It is highly recommended that you have a profressional low voltage electrician or experienced garage door installer...

Страница 14: ...de other rails part 4 into the bridges until they meet with the edges of Part 2 4 Stretch the chain across the length of the track Chain Tensioner Note Chain tensioner is installed on closing end of the rail while as the wire connector is on the open end 1 Slide chain tensioner part 5 into the closing end of the track away from the doors 2 Stretch the chain 3 Rotate it 90 degrees so it slides into...

Страница 15: ...p open end 2 Pull chain across the rail and lay chain over red limit stop until it reaches the wire connector 3 Rotate the chain 90 degrees and insert into chain holder of wire connector 4 Rotate back 90 degrees Note Do not tighten the chain on wire connector Tightening the Chain 1 Tighten the tensioner bolt with socket 1 2 until the washer hits the arrow or triangle ...

Страница 16: ...rtant to not overtighten Do not force the pieces together they should interlock easily Make sure they are firmly pressed against rail and the brackets are aligned For applications where you must drop the opener down from the ceiling we provide an option for a secondary ceiling bracket for additional support If you need an additional bracket please call to place an order Attaching the Swing Arm Fit...

Страница 17: ...he swing arm attachment on both sides 16 Tighten together Header Brackets 1 Install a header bracket part 11 centered above your doorway A second will be installed for direct mounting applications at the other end of the rail Note We do not provide additional ceiling mounted hardware for application where a drop down is required There is an option to purchase an additional ceiling mount bracket Pl...

Страница 18: ...ested positioning is in the middle of each inner door stile The rods may also be mounted up to 1 3 of the door s width from the center Note that the minimum distance from the center of the rail assembly to the center of the door brackets is 3 3 Install each bracket with short lag screws 4 Attach one u fitting to the threaded end of each push rod 5 Connect each rod to the door brackets by inserting...

Страница 19: ...rill a 3rd pilot hole 1 4 drill bit 1 6 1 3 5 over and 8 8 8 4 5 down from first hole on left 5 Insert wall plugs into pilot holes 6 Secure the control unit with two top screws and two washers 7 Align the unit check with level and firmly tighten screws with all three screws 8 Press the sealing plugs into the indentation to seal the housing 9 Route the wire connector cable and secure to the wall to...

Страница 20: ...control unit cover and gently lift upwards to remove cover 3 Unplug the connection cable for the membrane keypad from the unit 4 Place the battery pack in the control unit cover and fasten with the two cable binders 5 Plug the battery pack plug into the ACCU battery slot on the control board 6 Set DIP switch 3 to ON on the control unit only 7 Plug the connection cable for the membrane keyboard bac...

Страница 21: ...iver of the safety sensors set can range up to a maximum of 20 If you have a runtime of over 20 for a single door please contact customer service The distance from the floor must be selected so that an obstacle of 6 high can be reliably detected This corresponds to a distance of 2 from the bottom edge of the installation bracket to the floor Mount one safety sensor to the left and one to the right...

Страница 22: ...d Limit Stop 1 Disengage the motor Pull the red chord emergency release until it disengages This will allow you to move the door freely to see where the door needs to stop 2 Place the doors in open position 3 Position the red stop accordingly so it engages with the motor carriage Tighten the limit back down 4 Place the doors in the halfway open position Re engage the motor by pulling the red emerg...

Страница 23: ...bending breaking hardware Push 1st button on the remote to stop the door right before the doors hit the jamb 5 Hold down the 1st button on the remote to activate the hop function The opener will make a small jump forward Release quickly 6 Repeat until you reach the desired stop location Note An alternate solution is use something like 2x4 wood planks or other form of sturdy brace to stop the door ...

Страница 24: ...nds This will delete limit settings without resetting entire opener 2 Begin autoset process again starting on page 23 and after step 6 follow below steps 3 Pull the emergency release cord to disengage the motor 4 Activate the hop function each hop equals a 1 4 distance in programming The motor will not move 5 Pull emergency cord to engage the motor and continue with step 7 Troubleshooting 1 Opener...

Страница 25: ... to clone it 5 The opener light will remain steady 6 Second remote is programmed Homelink See page 43 of Sommer manual for programming information Note While programming homelink to the vehicle it will go through a learn cycle at least 3 4 times Not compatible with car2u or Tesla Homelink is on a 310 frequency Homelink will be installed into the first four prongs on the USART Please see below diag...

Страница 26: ...n of ACCU for install MEMO Memory extension from 40 commands up to 450 commands Easy to install and will work without programming plug and play When plugged in the MEMO transfers data from internal memory to the MEMO and stores information The MEMO must be remained plugged in At any time the data can be transferred back to the internal memory or deleted SOMLINK Is a service tool for adjusting and ...

Страница 27: ...usted with our SOMlink device For additional information please contact us directly at1 253 853 3815 Outdoor Keypad Keypad Activation 1 Press and hold the M button for about 8 seconds Both red and amber LED lights will light up for about 2 seconds Note The lower amber light will flash until the upper red light comes on The keypad is not activated until the red LED illuminates Programming Access Co...

Страница 28: ...n the chain track or carriage will reduce conductivity This may result in faults due to inadequate electrical contact The use of unsuitable cleaning agents may damage the surface of the opener Clean with a dry lint free cloth only Service the opener regularly as directed below This ensures safe operation and a long service life of your opener How Often What How Once a month Test the emergency rele...

Страница 29: ...has been installed remove the control unit housing cover and disconnect the battery pack Check that the power is disconnected 2 Remove the loose dirt with moist lint free cloth From the carriage and the control unit housing From the track and the inside of the track 3 If applicable install the battery pack in reverse order of removal Cleaning Photo Eyes 1 Clean the housing reflectors with a moist ...

Страница 30: ...Please visit our website and download our most up to date manual Call us directly at 1 253 853 3815 for additional assistance ...

Отзывы: