Step D-13
BOTH OPERATORS OPEN SIMULTANEOUSLY
BOTH OPERATORS CLOSE SIMULTANEOUSLY
SEQ1 = ON SEQ2 = OFF
If SEQ1 is set to ON, and SEQ2 is set to OFF, the FIRST
OPERATOR and SECOND OPERATOR open and close
simultaneously.
FIRST OPERATOR OPENS FIRST,
SECOND OPERATOR CLOSES FIRST
SEQ1 = OFF SEQ2 = ON
If SEQ1 is set to OFF, and SEQ2 is set to ON, the FIRST
OPERATOR will open first, and the SECOND OPERATOR
will close first (see illustration).
FIRST OPERATOR OPENS FIRST,
FIRST OPERATOR CLOSES FIRST
SEQ1 = ON SEQ2 = ON
If SEQ1 is set to ON, and SEQ2 is set to ON, The FIRST
OPERATOR opens and closes first.
BOTH OPERATORS OPEN SIMULTANEOUSLY
SECOND OPERATOR CLOSES FIRST
SEQ1 = OFF SEQ2 = OFF
If both SEQ1 and SEQ2 are set to OFF, the FIRST
OPERATOR and SECOND OPERATOR open
simultaneously. The SECOND OPERATOR will close
first.
STEP D-14
Replace the control box cover. Turn the control box power switch ON and allow the
control board 15 seconds to energize. Set the closed gate positions for the first and
second operators (review step 18 on page 19).
Your automatic gate operator system is configured for dual pull-to-open gates.