Страница 2: ... FAULT OUTPUT NC COM NO 4 2 6 Dimensions 4 Chapter 3 Construction and Components 1 3 1 Exterior and Interior Construction 1 3 1 1 Display Area 2 3 1 2 Description of LEDs 2 3 1 3 Description of Keys 3 3 1 4 Zone Indication Panel 3 3 2 Components 4 3 2 1 Standard Components 4 3 2 2 Optional Components 5 3 3 Periphery Devices 6 3 3 1 A Series of Intelligent Fire Detectors 6 3 3 2 Modules 6 3 3 3 Loo...
Страница 3: ...s 23 6 1 2 Methods of Data Input 23 6 1 3 Unlocking and Locking the Keypad 23 6 2 User Operation Instruction Operator Password Required 24 6 2 1 Browsing messages 24 6 2 2 System Time Setup 29 6 2 3 Printer Setup 30 6 2 4 Delay Mode 30 6 2 5 Fire Alarm Acknowledgement Timer 31 6 2 6 Testing Mode 31 6 2 7 Start Stop 33 6 2 8 Disable Enable 33 6 3 Instructions for System Administrator Manager Passwo...
Страница 4: ... the appropriate Authority Having Jurisdiction AHJ for confirmation of specific requirements GST IFP8 Fire Alarm Control Panel FACP shall only be installed and serviced by trained specialists Disconnect all sources of power before servicing The control unit and associated equipment may be damaged by removing and or inserting cards modules or interconnecting cables while the unit is energized Remov...
Страница 5: ...f addressable points 9 5 Outputs Output to fire alarm devices 7 8 Control of fire alarm routing equipment 7 9 Output to fire protection equipment 7 10 Test Test condition 10 The power supply of GST IFP8 FACP complies with EN 54 4 requirements EN 54 4 Clause Power supply from the main power source 5 1 Power supply from the standby power source battery 5 2 Charger 5 3 Faults 5 4 In addition to funct...
Страница 6: ...ator C 9503 complying with EN54 17 The LCD can display 15 lines in total and 40 characters each line assisting the 17 LEDs in displaying important information individually The memory does not lose data even if power source is accidentally removed Automatically prompting operation steps for every alarm device and for smoke exhaust and fire suppression devices by field programming Sounder strobe int...
Страница 7: ...able Vencroft Gold and Platignum Nexans NX 200 and 200 Plus LPCB tested Prysmian FP 200 and 200 Gold Draka Firetuf and Firetuf Plus And all LPCB approved Fire cables 2 3 Communication Loop Parameters 2 3 1 RS485 Communication Loop NETWORK even I I O O Communication cable for connecting with up to 32 network FACPs I corresponds to B2 I corresponds to A2 O corresponds to B1 O corresponds to A1 A1 B1...
Страница 8: ...USB Standard USB printer cable The length of cable should be less than 3m RS485 Port Recommended Wiring subject to local installation codes GST fire cable Vencroft Gold and Platignum Nexans NX 200 and 200 Plus LPCB tested Prysmian FP 200 and 200 Gold Draka Firetuf and Firetuf Plus And all LPCB approved Fire cables Recommended Cable Length 1000m 2 3 3 CAN Communication Loop non loop circuit loop ci...
Страница 9: ...re cable Vencroft Gold and Platignum Nexans NX 200 and 200 Plus LPCB tested Prysmian FP 200 and 200 Gold Draka Firetuf and Firetuf Plus And all LPCB approved Fire cables Recommended Cable Length 1000m 2 5 Input Output Loop Parameters Recommended Wiring subject to local installation codes GST fire cable Vencroft Gold and Platignum Nexans NX 200 and 200 Plus LPCB tested Prysmian FP 200 and 200 Gold ...
Страница 10: ...l Panel Installation and Operation Manual Page 4 Output Current 0mA 1000mA End of Line Resistor 4 7kΩ 2 5 5 FAULT OUTPUT NC COM NO Contact Capacity 24VDC 1 0A In fault state NC and COM close NO and COM open 2 6 Dimensions 484mm 191mm 850mm ...
Страница 11: ...terior construction are shown in Fig 3 1 and 3 2 1 2 3 4 5 6 7 8 9 0 F1 F2 F3 1 2 3 5 4 484mm 850mm 191mm Fig 3 1 1 LCD 2 Indicators 3 Keypad 4 Zone indication board 5 Printer 1 2 3 4 5 6 14 8 9 10 11 13 12 7 Fig 3 2 1 Mother board 2 Slot 3 Power board 4 Power switch module 5 Filter 6 Battery 7 Air switch 8 Earth stud 9 Zone indication board 10 Keypad board 11 LCD 12 Switch board 13 LED board 14 P...
Страница 12: ...s when standby power is in fault After the fault is cleared it will go out Verify Yellow It illuminates when the FACP is at Stage 2 of verification System Fault Yellow It illuminates if the program encounters a dead halt After the system is rebooted only by powering off the FACP can system fault be cleared and this LED goes out Supervisory Yellow It illuminates when the FACP receives supervisory m...
Страница 13: ...ETUP User set up key operator password required For setting system time setting printing mode enabling disabling delay mode setting test mode setting fire alarm verification time viewing definition of loop devices viewing history records start stop and for disable enable operation Numerical and Alphabetic Keys 1 2ABC 3DEF 4GHI 5JKL 6MNO 7PQRS 8TUV 9WXYZ 0 For entering numbers letters and marks RES...
Страница 14: ...this panel will be numbered as No 1 with fixed LED numbers ranging from 1 to 70 and the pin XS2 on the other one could be shorted so that the panel is numbered No 2 with fixed LED numbers from 71 to 140 3 2 Components 3 2 1 Standard Components A standard FACP consists of mother board main board loop board power supply display area and zone indication panel Mother Board The mother board is installe...
Страница 15: ...the exit with paper cutter The printing head is installed inside the frame and the paper insert scoop is at its bottom The printer is fixed onto the front panel by the spring holders on the sides of the frame The paper scroll is installed on the frame with a flexible spindle The whole printer together with the frame is easily pulled out for paper replacement External Printer Card GST IFP8 has an o...
Страница 16: ...tectors mounted in the protected area transmit monitoring message to the FACP through Class A loop Every detector has its own address with which the FACP can monitor the alarm fault and normal status of the detectors 3 3 2 Modules GST IFP8 can connect with I 9300 Addressable Input Module and I 9301 Addressable Single I O Module I 9300 module is used for receiving normally open digital signal from ...
Страница 17: ...one or more detectors alarm fire the repeater panel can display the location and alarm message of the detectors with audible and visual signals Through communication loops it can be connected with FACPs disposing and displaying the data from the FACPs When monitoring several floors or several zones with one fire alarm control panel a repeater panel on each floor or in each zone can replace zonal f...
Страница 18: ...irement The main items to be examined are installation and operation manual key to the FACP and etc Check Internal Components and Interconnection inside the FACP All internal parts have been connected including optional units ordered before the FACP leaves the factory Therefore you can mainly check the zone indication panel and power supply and the connection among parts including the connection b...
Страница 19: ...s such as fire alarm is illuminated Check if the LEDs showing the state of system can be illuminated one by one Check if the LEDs showing the device state in zone indication panel are illuminated in turn Check if the buzzer can give loud alarm sounds 4 4 External Connection 4 4 1 Mains Connection GST IFP8 Fire Alarm Control Panel receives power from a 220VAC 230VAC 50Hz 60Hz supply The incoming po...
Страница 20: ... batteries according to Fig 4 2b and then connect with the battery terminal BAT black power board BAT Red power board Fig 4 2b Note Do not make the final battery connections until the installation is completed 4 4 3 Field Device Connection GST IFP8 connects with field devices through mother board Terminals on the mother board are shown in Fig 4 3 Caution Do not connect power to your device until y...
Страница 21: ... by the isolators will not be lost in case of short or open circuit with the loop and the FACP reports loop fault OUTPUT TO FPE It outputs according to settings in Section 6 3 2 when there is fire alarm It can be disabled and does not output when fire alarm occurs in disabled state It can be included into C E equation but cannot be set at delay mode The FACP reports fault when there is short or op...
Страница 22: ...t terminal OUTPUT TO SOUNDER as factory default Please remove it and keep it well before connection Connect the loop in correct polarity and add the resistor to the end of the line NOTE The sounder strobes are polarity sensitive Note polarity in connection The maximum current of the circuit depends on the number of sounder strobes Do not overload 4 4 3 2 Connection of OUTPUT TO FPE Connection of t...
Страница 23: ... are polarity sensitive Note polarity in connection The maximum current of the circuit depends on the number of fire supervisory device Do not overload 4 4 3 4 Connection of Class A Loops A Class A loop is shown in Fig 4 7 Fig 4 7 Note If more than 32 devices are connected to the loop loop isolators shall be used and each loop isolator shall not cover more than 32 detectors ALARM ROUTING Diode End...
Страница 24: ...0台控制器 Network 任一回路 Fig 4 8a Ring network is connected as shown in Fig 4 8b Fig 4 8b Monitor and control network is connected shown in Fig 4 8c through P 9935 communication Card P 9935 Communication Card RS232 RS485 USB PC COM COM USB CRT Line CRT Line USB Line Fig 4 8c Network Any Loop O O Maximum 32 FACPs through RS485 Maximum 100 FACPs through CAN Network Any loop FACP FACP I I FACP FACP FACP FA...
Страница 25: ...rcuit connected with the FACP Measure the insulation resistance between loops and between loops and ground which should be more than 20MΩ Measure the load of detection loops which should be more than 1kΩ The resistance between cables of ALARM ROUTING OUTPUT TO SOUNDER and OUTPUT TO FPE should be equal to the end of line resistance 4 5 2 Device Registration Step 1 Set the FACP into commission state...
Страница 26: ...s and C E equations by the software GstDef2 1 Defining Tool through a PC and download the definitions to the FACP Refer to GstDef2 1 Defining Tool User s Manual for detailed operation 4 7 Field Device Commission After connection definition and download of device and C E equations you can power up the FACP and start commission The following steps are for reference 1 Complete the labels of zone indi...
Страница 27: ...ally and only POWER LED lights In status bar only the status of FIRE ALARM ROUTING FAR OUTPUT TO FPE FPE and OUTPUT TO SOUNDER OTS is displayed If the system is in commission state there is an x mark at the right top of the screen In standby state this mark will disappear The project name can be defined by the defining tool software through a PC which can have maximum 32 characters FAR OK FPE DIS ...
Страница 28: ...acknowledge the fire alarm ENTER FAR OK FPE DIS OTS OK 20 44 30 Press ACK to acknowledge Press F1 to start Zone sounder Press F2 to start Local output Press ENTER to view detail Press L R scroll to switch inf type 001 May 07 09 20 Zone001 Sum002 032 Room 101 and Living Room 102 Abcdfgjklmm Built Fire Sum 002 001 002 May 07 09 20 Zone002 Sum001 030 Room 102 and Living Room 104 Abcdfgjklmm Built Las...
Страница 29: ...nstaller or manufacturer for repair 5 3 Pre alarm In case of a pre alarm the Pre Alarm LED will illuminate and the buzzer of the FACP will sound continuously 5 3 1 Display of Pre alarm Fig 5 4 FAR OK FPE DIS OTS OK 20 44 30 Press ACK to start verification Press ENTER to view detail Press L R scroll to switch inf type 001 May 07 09 20 Zone001 Phase1 Room 101 and Living Room 102 Abcdfgjklmm Built Pr...
Страница 30: ...y is not met the pre alarm will be automatically cancelled If the condition is met the pre alarm will automatically change to a fire alarm 5 3 2 2 Disposal of Pre alarm Message in Day Mode In day mode if a pre alarm comes the screen will display the delay time Stage 1 for acknowledgement of the pre alarm Pressing ACK the FACP will enter the delay time Stage 2 for verifying if it s a true fire alar...
Страница 31: ...e FACP has to be reset by rebooting Fault relay outputs Keypad fault The panel reports keypad fault if its keypad circuit is in fault It lights the FAULT and SYSTEM FAULT LED The LCD displays hardware fault The panel generates continuous alarm sound Fault relay outputs The keypad cannot be used The FACP can monitor fire alarm After the fault is removed the FACP has to be reset by rebooting Ground ...
Страница 32: ...he fault cannot be cleared for some reason and enable it when the fault is removed 5 7 Rules for Message Display If there are multiple messages in the system they will be displayed in the following order fire alarm pre alarm supervisory fault disable 1 The earliest fire alarm is displayed in priority The latest pre alarm supervisory fault and disabled message are displayed in priority 2 In any dis...
Страница 33: ...ge into its running log If the fire alarm fault or supervisory information still exists after reset operation the system will display corresponding states Otherwise it returns to normal operation state 6 1 2 Methods of Data Input Choosing a character key all characters disappear and the display shows the newly input one The cursor will indicate the next input position The cursor always indicates t...
Страница 34: ...E SETUP 5 ACKNOWLEDGE TIMER 6 TEST SETUP 7 START STOP DEVICE 8 DISABLE ENABLE Operator password Fig 6 1 6 2 1 Browsing messages Choosing 1 on the screen shown in Fig 6 1 will enter message browsing screen as in Fig 6 2 FAR OK FPE DIS OTS OK 20 44 30 BROWSE 1 BROWSE DEVICES 2 BROWSE ZONES 3 BROWSE GROUPS 4 BROWSE DUPLICATED ADDRESS 5 BROWSE PANEL STATUS 6 BROWSE C E EQUATIONS 7 HISTORY LOG Fig 6 2 ...
Страница 35: ...nt Loop Devices Inf FAR OK FPE DIS OTS OK 20 44 30 Loop01 Loop Card Devices sum 242 D001 Zone 101 Loop 02 HEAT DETECTOR ROOM101 D002 Zone 101 Loop 02 HEAT DETECTOR ROOM102 D003 Zone 101 Loop 02 HEAT DETECTOR ROOM103 D004 Zone 101 Loop 02 HEAT DETECTOR ROOM104 D005 Zone 101 Loop 02 HEAT DETECTOR ROOM105 Fig 6 3 On the screen for viewing messages if there is no fire alarm pressing F1 can print devic...
Страница 36: ...p 02 HEAT DETECTOR ROOM102 D003 Zone 001 Loop 02 HEAT DETECTOR ROOM103 D004 Zone 001 Loop 02 HEAT DETECTOR ROOM104 D005 Zone 001 Loop 02 HEAT DETECTOR ROOM105 Zone 001 Devices sum 0030 Led 001 Building 001 Fig 6 4 6 2 1 3 Browsing Groups Choosing 3 on the screen shown in Fig 6 2 will enter the screen for browsing groups as in Fig 6 5 FAR OK FPE DIS OTS OK 20 44 30 GROUP SUM 001 DEVICE SUM 0003 ENT...
Страница 37: ...m 000 Loop02 Loop Card Dupli Add sum 000 Fig 6 6 6 2 1 5 Browsing FACP Status Choosing 5 on the screen shown in Fig 6 2 will enter the screen for browsing the status of FACP as in Fig 6 7 FAR OK FPE DIS OTS OK 20 44 30 PANEL STATUS LOOP 02 POINTS 0000 CRT CARD 00 NETWORK CARD 00 Main power voltage 220V Standby power voltage 26 6V Main borad software version V Fig 6 7 6 2 1 6 Browsing Cause and Eff...
Страница 38: ... is the message generated by the FACP when there is fire alarm or action of device A result is composed of the following items On the screen for browsing C E equation if there is no fire alarm message pressing F1 as prompted can print out all C E equations 6 2 1 7 Browsing History Log Choosing 7 on the screen shown in Fig 6 2 entering super password followed by ENTER will enter the screen for brow...
Страница 39: ...ode the log can be printed out by choosing ENTER during browsing Please note the third entry INITIALIZATION requires super password followed by ENTER 6 2 2 System Time Setup Choosing 2 on the screen shown in Fig 6 1 will enter the screen for setting up system time as in Fig 6 10 Enter the time at the position of flashing cursor and press for the next data Choosing ENTER after setup will get the ne...
Страница 40: ...ry log FAR OK FPE DIS OTS OK 20 44 30 PRINTER SETUP 1 DISABLE 2 Only Fire 3 All History Fig 6 11 6 2 4 Delay Mode Choosing 4 on the screen shown in Fig 6 1 will enter the screen for delay mode setup as in Fig 6 12 FAR OK FPE DIS OTS OK 20 44 30 DELAY MODE SETUP 1 Disable 2 Enable Fig 6 12 Choosing 1 Disable in the above screen delay output of all output type devices is not allowed and the FACP ent...
Страница 41: ...lly change to fire alarm 6 2 5 Fire Alarm Acknowledgement Timer Choosing 5 on the screen shown in Fig 6 1 will enter the screen for setting up the time for Stage 1 and Stage 2 of acknowledgement timer as in Fig 6 13 FAR OK FPE DIS OTS OK 20 44 30 ACKNOWLEDGE TIMER Please input the Pre Alarm ACK time Stage1 Default 30S 00 M 30 S Please input the Pre Alarm verify time Stage2 Default 2M 02 M 00 S Fig...
Страница 42: ...ng up zones for testing as shown in Fig 6 16 where the zone number to test and the testing mode can be entered If a zone is set to test mode the zonal fault LED on the zone indication panel should illuminate If a fire alarm comes from the zone the system will automatically display and print the fire alarm message and light the zonal fire LED on the zone indication panel but the general Fire LED wi...
Страница 43: ...STOP DEVICE Stop Zone 001 Dev 001 Type 03 BEAM DETECTOR 1 for starting devices Fig 6 17 6 2 8 Disable Enable Choosing 8 on the screen in Fig 6 1 will access disable enable menu These operations are used for faulty field devices that are not able to be repaired in time In such cases they are to be disabled temporarily and re enabled after the problems are resolved Disable Enable operation is availa...
Страница 44: ...isabled Commission 12 58 01 DISABLE ENABLE DEVICE 1 DISABLE DEVICE 2 ENABLE DEVICE FAR OK FPE DIS OTS OK 20 44 30 DISABLE ENABLE DEVICE Disable Zone 001 Dev 001 Type 03 BEAM DETECTOR FAR OK FPE DIS OTS OK 20 44 30 DISABLE ENABLE DEVICE Enable Zone 001 Dev 001 Type 03 BEAM DETECTOR 1 for disabling devices 1 DISABLE DEVICE 2 ENABLE DEVICE 1 DISABLE DEVICE 2 ENABLE DEVICE Fig 6 19 6 3 Instructions fo...
Страница 45: ...LOCAL OUTPUT SETUP 3 WORKING STATE SETUP 4 COMMISSIONING Manager password Fig 6 20 6 3 1 System Resource Setup Choosing 1 on the screen of Fig 6 20 the FACP enters the menu for setting up system resources as in Fig 6 21 FAR OK FPE DIS OTS OK 20 44 30 PROGRAMMING 1 DEVICE SETUP 2 ZONE SETUP 3 COMMUNICATION SETUP 4 DAY NIGHT TIME SETUP 5 MODIFY PASSWORD 6 C E EQUATION SETUP 7 DEVICE TYPE SETUP Fig 6...
Страница 46: ...ollowed by ENTER then the device type zone attribute and note text can be entered on the screen shown in Fig 6 23 below FAR OK FPE DIS OTS OK 20 44 30 DEVICE SETUP Zone 1 999 001 Device Type 01 OPTICAL SMOKE Attribute 0 6 1 Text 40 Byte Loop 01 Address 1 242 001 Fig 6 23 Choosing ENTER after programming of one detector will enable the setup of the next one FAR OK FPE DIS OTS OK 20 44 30 DEVICE SET...
Страница 47: ...report a fire alarm 2 Dependency Type B If a zone is set as Type B dependency the alarm of a detector from this zone will be reported as a pre alarm and when there is another detector alarm from any zone the FACP will report a fire alarm Sounder mode setup 0 Sound by zone fire This means the sounder will output if only there is fire alarm from this zone 1 On C E This means the sounder will output ...
Страница 48: ...NICATION SETUP 1 MONITOR INTERFACE 2 NETWORK INTERFACE Fig 6 25 6 3 1 4 Setting Start Stop Time of Day Mode Choosing 4 on the screen of Fig 6 21 will enter the screen for setting start and stop time of day mode If delay mode is enabled the system will automatically enter delay mode in during day time and enter delay disabled mode outside the range of day time FAR OK FPE DIS OTS OK 20 44 30 DAY NIG...
Страница 49: ...M SETUP 6 3 1 6 C E Equation Setup Choosing 6 on the screen of Fig 6 21 will enter the screen for cause and effect C E setup for creating modifying deleting and initializing C E equation FAR OK FPE DIS OTS OK 20 44 30 C E EQUATION SETUP 1 CREATE 2 MODIFY 3 DELETE 4 INITIALIZATION Fig 6 28 6 3 1 6 1 Format of Cause and Effect Equation The Cause and Effect equation is a logical expression for defini...
Страница 50: ...uation 4 There are two types of relational operators and x in which refers to or and x refers to and 5 The figure appearing after the equal mark can be 00 to 99 which is to be multiplied by 10 to represent a time within 0s to 600s 6 Wildcard character asterisk is allowed to used in the equation to represent number 0 to 9 It can be used either before or after the equal mark When it appear in the co...
Страница 51: ...ation 6 3 1 6 5 Initializing C E Equations Choosing 4 in the screen of Fig 6 28 and entering super password on prompt will delete all C E equations 6 3 1 7 Device Type Setup Choosing 7 on the screen of Fig 6 21 will enter the screen for device type setup Device types can be chosen using User Defined devices can be modified by the user After modification pressing ENTER will saved the modified devic...
Страница 52: ...ered on one fire alarm signal 1 Output will be triggered on fire alarm signals from more than 1 device which may be from different zones 2 Output will be triggered on C E setup The delay time cannot be set for F P E A which would always output immediately 6 3 3 Working State Setup Choosing 3 on the screen in Fig 6 20 will access working state setup menu As shown in Fig 6 31 the FACP can be optiona...
Страница 53: ...LIZATION 8 NETWORK SCAN Fig 6 32 Choosing 1 in the above screen can register all loop devices Choosing 2 can check loop devices with duplicated addresses and find out if the detector device types are in compliance with originally defined If not a fault message will appear Choosing 3 in the above screen will access the menu for modifying device address as shown in Fig 6 33 FAR OK FPE DIS OTS OK 20 ...
Страница 54: ... IN ANALOG MODE Loop 01 Address 1 242 001 COMMAND 00 STEP 00 00 PATROL 01 REGISTER 02 START 03 REAL TIME DATA Fig 6 34 Choose 6 on the screen of Fig 6 32 for commission in digital mode as in Fig 6 35 FAR OK FPE DIS OTS OK 20 44 30 COMMISSION IN DIGITAL MODE Loop 01 Address 1 242 001 COMMAND 00 00 00 00 02 00 00 00 SERIAL NO 03 09 00 00 REAL TIME DATA 04 09 01 NO SELECTED WATCH 02 06 00 00 CONFIGUR...
Страница 55: ...scent current when the FACP is with no load ILmax 2 4A is the maximum loop current IFout 0 2A 0 2A 1A 1 4A which is the alarm output current The FACP provides 3 fire alarm outputs output current of each is 0 2A 0 2A and 1A respectively T1 is the monitoring time when the FACP is full loaded which shall be at least 24 hours according to EN 54 4 T2 is the alarm time which shall be at least 30 minutes...
Страница 56: ... a Check and replace low voltage switch power b Check the connection to display board 2 Display AC Fault after power up No AC power Check and connect AC wire 3 Display Battery Fault after power up a Loose connection with battery b Battery discharged or damaged a Open the power box and check relative parts b Power up for more than eight hours with the AC power supply if the fault still exists repla...
Страница 57: ...D 5V XP1 XP1 27V GND BAT BAT 5V GND GND 24V TX RX 5V GND XT5 XT2 XT6 XT3 AC1 AC2 L G N 5V GND V V 1 2 3 4 5 7 8 6 9 10 13 11 12 XS1 5V GND GND 24V TX RX 13 14 B1 Lining Board Earth Stud Cabinet Earth Stud 1 LCD 2 Keypad Board 3 LED Board 4 Switch Board 5 Mother Board 6 Zone Indication Board 1 7 Zone Indication Board 2 8 Printer 9 AC DC Power Module 10 Power Supply Board 11 Filter 12 Air Switch 13 ...
Страница 58: ...not connected 9 Sounder A Sounder output loop fault Souder output loop opens shorts or the end of line resistor is not connected 10 ALARM ROUTINGA Alarm routing fault Alarming routing opens shorts or the end of line resistor is not connected 11 Power Board Power board fault Power board damaged or cannot communicate with main board 12 Loop Board Loop board fault Loop board damaged or cannot communi...
Страница 59: ...INED 10 FLOW SWITCH 11 MCP BG Output Control Devices 12 SOUNDER STOBE 13 SOUNDER 14 FLASHER 15 LIFT 16 FIRE DAMPER 17 FIRE DOOR 18 AHU 19 EXTRACT FAN 20 BMS 21 USER DEFINED 22 USER DEFINED 23 USER DEFINED 24 USER DEFINED 25 USER DEFINED 26 USER DEFINED 27 USER DEFINED 28 USER DEFINED 29 USER DEFINED 30 USER DEFINED Fault Signal Input Devices 31 TROUBLE MONITOR 32 PSU 33 USER DEFINED 34 USER DEFINE...
Страница 60: ... NET SounderA 56 USER DEFINED 57 USER DEFINED 58 USER DEFINED 59 USER DEFINED 60 USER DEFINED 61 USER DEFINED 62 USER DEFINED 63 USER DEFINED 64 USER DEFINED 65 NET F P E A Local Devices 66 Undefine 67 Loop SW 68 Loop Board 69 CONTROL Panel 70 ZoneDir Board 71 AC Power 72 Battery 73 Keypad Board 74 Ground F 75 Undefine 76 Loop Short 77 Loop Board 78 Delay Mode 79 Power Board 80 CRT Board 81 F P E ...
Страница 61: ...Intelligent Fire Alarm Control Panel Installation and Operation Manual Page 51 89 Undefine 90 Undefine 91 Undefine 92 Undefine 93 Undefine 94 Undefine 95 Undefine 96 Undefine 97 Undefine 98 Undefine 99 Undefine ...
Страница 62: ...E DEPLICATED ADDRESS BROWSE PANEL STATUS BROWSE C E EQUATIONS BROWSE LOG CLOCK PRINTER SETUP DISABLE Only Fire All History DELAY MODE Disable Enable ACKNOWLEDGE TIMER TEST MODE LED BUZZER TEST LOCAL_OUTPUTS TEST SETUP TEST ZONES CANCEL TEST ZONES START STOP START STOP DEVICE DISABLE ENABLE DIS ENABLE DEVICE BY CODE DIS ENABLE DEVICE BY ADDRESS DIS ENABLE ZONE DIS ENABLE SOUNDER ...
Страница 63: ... SETUP COMMUNICATION SETUP DAY NIGHT TIME SETUP MODIFY PASSWORD C E EQUATION SETUP DEVICE TYPE SETUP LOCAL OUTPUT SETUP WORKING STATE SETUP COMMISSION MONITORING COMMISSIONING DEVICE LEARN DUPLICATED ADDRESS CHECK MODIFY ADDRESS MODIFY DEVICE SENSITIVITY COMMISSION IN ANALOGUE MODE COMMISSION IN DIGITAL MODE SYSTEM INITIALIZATION ...
Страница 64: ...s not required by EN54 2 Preface 12 2 1 b Power requirement for recommended operation Section 2 1 2 2 Maximum capacity per detection circuit Section 2 4 Maximum capacity per FACP Chapter 1 Electrical ratings for inputs and outputs Section 2 5 Communication parameters on transmission paths Section 2 4 2 5 Fuse ratings Section 8 2 12 2 1 c Installation information Section 4 1 4 2 4 3 4 4 12 2 1 d Co...
Страница 65: ...IFP8 SP GST IFP8 IT GST IFP8 FR GST IFP8 TK WEEE Information 2012 19 EU WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points 548p 02 2831 CPR F0994 GST 0204 01 09 2831 CPR F0...
Страница 66: ...Gulf Security Technology Co Ltd No 80 Changjiang East Road QETDZ Qinhuangdao Hebei P R China 066004 Tel 86 0 335 8502434 Fax 86 0 335 8502532 service gst fs utc com www gst com cn ...