Geophysical Survey Systems, Inc.
SIR® 4000
Manual
MN72-433 Rev F
102
b)
Select calibration distance – The default distance is 10
meters or feet. This distance can be changed, and a
longer distance provides a more accurate calibration.
c)
Position Antenna on the Start mark – The antenna or
system can be positioned anywhere at the start if you
use the same point on the antenna or system when you
stop.
d)
Press the Start button – This is the green Start button
located on the keypad of the SIR 4000.
e)
Move antenna to the stop mark – match to the same
location on the antenna or system where you started.
f)
Press Stop button – This is the red Stop button located
on the keypad of the SIR 4000.
If necessary, you can manually enter the calibration value:
1
Use either the Control Knob or Arrow keys to navigate to the New Calibration Value box.
2
Press the Control Knob of the Enter key to highlight the New Calibration Value box. Rotate the
Control Knob or use the up and down arrows to enter in the correct value.
3
Click the right arrow to save and exit.
4
Once the desired survey wheel calibration is achieved
select Apply. The current value will be saved and the
Calibrate SW menu will close. Press the Quit Toolbar
key to return to the main Introduction Screen.
5
GPS Config:
Enter GPS parameters based on the settings
for your GPS. Press the green start button to begin GPS
data collection. Once a GPS fix is acquired the GPS
Configuration window will show the Fix Quality, Number
of Satellites, and HDOP. Use the Control Knob to
highlight Apply, and press down on the Control Knob.
Step 3 – Data Collection in Distance Mode
1
To begin data collection press the green Start button once.
2
At the end of your profile, press the red Stop button once or press and hold the green Start button.
This halts the collection of the current data file; you won’t be able to scroll across the profile or
perform any of the functions on the command bar.
3
If AutoSave is set to On the file will automatically be saved. A new file will immediately begin using
the same collection parameters as the previous file.
4
If AutoSave is set to Off a system prompt will pop up giving you the option to save or discard the file.
Choose to save or discard using the Control knob or the Directional Keys.
5
To continue data collection after choosing to save or discard a file, position yourself at the beginning
of your next profile. Then press the green Start button one time to begin the next data file. The
Содержание SIR 4000
Страница 1: ......
Страница 4: ......
Страница 116: ...Geophysical Survey Systems Inc SIR 4000 Manual MN72 433 Rev F 110 ...
Страница 140: ...Geophysical Survey Systems Inc SIR 4000 Manual MN72 433 Rev F 134 ...
Страница 150: ...Geophysical Survey Systems Inc SIR 4000 Manual MN72 433 Rev F 144 ...
Страница 156: ...Geophysical Survey Systems Inc SIR 4000 Manual MN72 433 Rev F 150 ...