Geophysical Survey Systems, Inc.
SIR® 4000
Manual
MN72-433 Rev F
29
Show O-Scope
Toggles the O-Scope display On or Off for use during
data collection. Selecting Off will not turn off the
O-Scope display in the Setup Screen.
•
During data collection you will not have the
option to turn the O-Scope display On or Off.
This choice is only made while in the Setup
Screen.
•
Toggle Show O-Scope On or Off by pressing
the Control Knob or the Enter key.
Show Hyperbola
Toggles a hyperbola On or Off while in setup
or during collection. The hyperbola appears
at the intersection of the vertical and
horizontal cursor. By default the horizontal
cursor is placed at the top of the data display.
•
The hyperbola is used during data
collection to do real-time hyperbola
fitting. Hyperbola fitting measures
the geometry of visible hyperbolas in
the data to generate an estimated
Dielectric Constant.
•
During data collection you’ll also
have the option to turn the hyperbola
On or Off.
•
Toggle Show Hyperbola On or Off by pressing the Control Knob or the Enter key.
Colormap
This menu option offers 30 available Colormap options (i.e. color tables).
Select the menu by pressing the Control Knob or Enter key and then scroll
through Colormap #0-29. The currently selected Colormap appears at the top
of the O-Scope display and indicates how colors are distributed between
negative (left) and positive (right) amplitude changes.
Color Stretch
Selecting Color Stretch allows you to adjust how the selected Colormap is distributed over a scan’s
amplitude range. A Color Stretch greater than one (1) compresses the colors towards zero (0). A Color
Stretch less than one (1) expands the colors towards the maximum negative and positive amplitudes.
Left Color Stretch = 0; Middle Color Stretch = 1; Right Color Stretch = 3
Содержание SIR 4000
Страница 1: ......
Страница 4: ......
Страница 116: ...Geophysical Survey Systems Inc SIR 4000 Manual MN72 433 Rev F 110 ...
Страница 140: ...Geophysical Survey Systems Inc SIR 4000 Manual MN72 433 Rev F 134 ...
Страница 150: ...Geophysical Survey Systems Inc SIR 4000 Manual MN72 433 Rev F 144 ...
Страница 156: ...Geophysical Survey Systems Inc SIR 4000 Manual MN72 433 Rev F 150 ...