Geophysical Survey Systems, Inc.
SIR® 4000
Manual
MN72-433 Rev F
104
5
If AutoSave is set to Off a system prompt will pop up giving you the option to save or discard the file.
Choose to save or discard using the Control knob or the Directional Keys.
6
To return to the Collect Setup screen if AutoSave is set to On, push and hold down the red Stop
button for two seconds. The current file will automatically be saved and you will return to the Collect
Setup screen. If AutoSave is set to Off, press the red Stop button one time. A system prompt will pop
up giving you the option to save or discard the current file. Once an option has been selected push
and hold down the red Stop button for two seconds and you will return to the Collect Setup screen.
6.4: Setting Up for Point Mode Data Collection in Digital 2D
The third data collection mode on the SIR 4000 is for Point mode data collection. This mode is most
useful for deep geophysical investigations or data collection over difficult, broken terrain.
Point mode is for recording individual scans over an area. These scans are combined to produce a profile
similar to the other collection modes. The scan spacing (horizontal resolution) of Point-based data profiles
is a function of how far apart you set your collection points.
Radar Menu
1
Collect Mode:
Set to Point.
2
Depth/Time Range:
There are two options for setting the depth or time range.
3
Scans/Unit:
This is the number of scans that will be collected every foot or meter. This number will
affect how the horizontal scale is displayed during data collection.
Process Menu
1
Static Stacking:
Point data is typically collected with some static stacking. A good default value
here is 64. The system will take 64 scans at each scan location and average them together to output a
single scan. This is done to minimize high-frequency, random noise.
Output Menu
1
Spacing, Amplitude, and Fill:
Check that you are using your preferred display settings for Point
Mode.
Data Collection in Point Mode
1
To begin data collection press the green Start button one time. The screen will appear with one scan
trace on the left side of the data display screen and the rest of the data display will be blank.
2
Press the Next Point control button to collect subsequent scans. The Scan number will update in the
Information Bar at the top of the screen as additional scans are added.
At the end of your profile, press and hold the red Stop button for two seconds. If AutoSave is set to On
the profile will be saved and you will return to the Collect Setup menu. If AutoSave is set to Off a system
prompt will give you the option to save or discard the current file. Once an option has been selected press
and hold the red Stop button again and you will return to the Collect Setup screen.
Содержание SIR 4000
Страница 1: ......
Страница 4: ......
Страница 116: ...Geophysical Survey Systems Inc SIR 4000 Manual MN72 433 Rev F 110 ...
Страница 140: ...Geophysical Survey Systems Inc SIR 4000 Manual MN72 433 Rev F 134 ...
Страница 150: ...Geophysical Survey Systems Inc SIR 4000 Manual MN72 433 Rev F 144 ...
Страница 156: ...Geophysical Survey Systems Inc SIR 4000 Manual MN72 433 Rev F 150 ...