Geophysical Survey Systems, Inc.
SIR® 4000
Manual
MN72-433 Rev F
45
A Hilbert Transform will change a radar signal
represented as a time series into its magnitude
(via envelope detection) phase). Toggle Hilbert
Transform On or Off by pressing the Control
Knob or Enter key.
Show Hyperbola:
Toggles a hyperbola On or
Off while in setup or during playback. The
hyperbola appears where the vertical and
horizontal cursors meet. The horizontal cursor
is placed at the top of the data display by
default.
•
The hyperbola is used during data
collection to do real-time hyperbola
fitting. Hyperbola fitting measures the
geometry of visible hyperbolas in the data to generate an estimated Dielectric Constant.
•
During data collection you can turn the hyperbola On or Off.
•
Toggle Show Hyperbola On or Off by pressing the Control Knob or the Enter key.
Colormap:
This menu option offers 30 available Colormap options (i.e. color tables).
Select the menu by pressing the Control Knob or Enter key and then scroll through
Colormap #0-29. To preview the different Colormaps, if the O-Scope is not displayed
during data collection, return to the Setup Screen->Output Menu.
Color Stretch:
Selecting Color Stretch allows you to adjust how the selected
Colormap is distributed over a scan’s amplitude range. (See Output Distance Mode
above for screenshots and additional information).
Color Slide:
Selecting Color Slide allows you to shift the center point (point of zero
amplitude) of the selected Colormap over a scan’s amplitude range. To preview Color
Slide, if the O-Scope is not displayed during data collection, return to the Setup
Screen->Output Menu. (See Output Distance Mode above for screenshots and additional information).
Содержание SIR 4000
Страница 1: ......
Страница 4: ......
Страница 116: ...Geophysical Survey Systems Inc SIR 4000 Manual MN72 433 Rev F 110 ...
Страница 140: ...Geophysical Survey Systems Inc SIR 4000 Manual MN72 433 Rev F 134 ...
Страница 150: ...Geophysical Survey Systems Inc SIR 4000 Manual MN72 433 Rev F 144 ...
Страница 156: ...Geophysical Survey Systems Inc SIR 4000 Manual MN72 433 Rev F 150 ...