Malfunction
60 | 80
B
A
_
T
D3
-B
S
0
0
1
e
n
_
0
1
4
_
so
ft
liQ
-SD
8.1.2
Error messages (red symbols)
Display shows
Explanation
Remedy
Power failure > 5 minutes
Only displayed if
detection is activated.
Water softener will
perform a regeneration
as soon as the electrical
power supply returns.
If there is a power
failure, any regeneration
in progress at the time is
stopped and then
continued afterwards.
Check the electrical connection.
Reset the clock of the water softener
if there is a power failure > 3 days
(refer to chapter 6.2).
Start a manual regeneration (refer to
chapter 6.5).
Salt supply used up!
Refill
immediately!
(Order no. 127 001)
Cavity under the salt.
Break up incrustations with a
suitable tool.
Salt supply used up.
Refill salt tablets (refer to
chapter 6.3).
Confirm with Rectify.
Water pressure too low.
Increase the flow pressure to min.
2.0 bar.
Chlorine cell worn.
Brine filling orifice,
injector, injector sieve or
brine valve clogged.
Notify Grünbeck's technical service /
authorised service company.
Malfunction at the drive
to the regeneration control valve!
Step monitoring of
regeneration motor or
connecting cable
defective.
Notify Grünbeck's technical service /
authorised service company.
Regeneration water meter
Quantity not reached!
Regeneration water
meter is not supplying
any pulses.
Connecting cable
defective.
Water supply interrupted.
Safety float on brine
valve closed.
Check the water supply.
Notify Grünbeck's technical service /
authorised service company.
Water meter
soft water defective
Soft water meter is not
emitting any pulses.
Connecting cable
defective.
Water supply interrupted.
Check the water supply.
Notify Grünbeck's technical service /
authorised service company.