Operation
52 | 80
B
A
_
T
D3
-B
S
0
0
1
e
n
_
0
1
4
_
so
ft
liQ
-SD
The following menu items are only available for softliQ:SD21 and softliQ:SD23:
Menu items
Settings / remarks
Inputs and
outputs
Programmable
output function*
Regeneration water delivery pump
– factory
setting
This setting must be made in connection with the
regeneration water delivery pump available as
an accessory (refer to chapter 3.7).
Contact closed (regeneration water delivery
pump running) during the regeneration steps of
first filtrate, salting, displacement and backwash.
Regeneration message
Contact closed during the entire regeneration.
Function fault
signal contact*
N. C.
– factory setting
Contact closed if mains voltage is applied and
there is no fault.
N. O.
Contact closed in the event of a malfunction.
Programmable
input function
Leakage detection
– factory setting
If a leakage is detected at the installation site of
the softliQ system via the water sensor,
the message "Leakage at the softliQ installation
site" is displayed.
Regeneration lock
The regeneration lock is active as long as the
contact at the programmable input is closed;
manually released and automatic regenerations
after a power failure take priority. A regeneration
that has already been started is not cancelled.
Release of regeneration
Start of a partial regeneration if the contact at the
programmable input closes.
* Only with softliQ:SD23
6.10
Sending an email if there is a malfunction
If your softliQ water softener is connected to your user account in the Grünbeck Cloud, you
will be notified by e-mail in the event of a fault.