Technical specifications
68 | 80
B
A
_
T
D3
-B
S
0
0
1
e
n
_
0
1
4
_
so
ft
liQ
-SD
Connection data
softliQ:SD18
softliQ:SD21
softliQ:SD23
Nominal connection diameter
DN 25 (1" male thread)
Min. drain connection.
DN 50
Rated voltage range
[V]
100 - 250
Rated frequency
[Hz]
50 - 60
Rated consumption (during regeneration, temporarily)
[W]
8
14
Softening power consumption, if display, Wi-Fi and
illuminated LED ring are switched off
(illuminated LED ring only for softliQ:SD21 and softliQ:SD23)
[W]
< 3.5
Protection / protection class
IP54/
Performance data
softliQ:SD18
softliQ:SD21
softliQ:SD23
Nominal pressure
PN 10
Rated pressure
[MPa]/
[bar]
1.0/10
Min. / max. operating pressure (recommended)
[bar]
2.0/8.0 (4.0)
Nominal flow (0 °dH, 0 °f, 0 mol/m³)
acc. to DIN EN 14743 at a pressure loss of 1.0 bar
(theoretical value))
[m³/h]
1.8
2.1
2.3
Nominal flow at a pressure loss of 1.0 bar acc. to
DIN 19636
(raw water hardness 20 °dH (35.6 °f, 3.56 mol/m³),
soft water hardness 8 °dH (14.2 °f, 1.42 mol/m³))
[m³/h]
3.0
3.5
3.8
Nominal capacity variable
[m³ x °dH]
[m³ x °f]
[mol]
6 - 14
11 - 25
1.1 - 2.5
8 - 20
14 - 36
1.4 - 3.6
9 - 23
16 - 41
1.6 - 4.1
Capacity per kg of regeneration salt
[mol/kg]
6.7 - 4.5
7.1 - 4.5
Regeneration time for a complete regeneration
[min.]
20 - 40
Regeneration (1x per day) in case of reduction in capacity
[%]
> 50
Filling volumes and consumption data
softliQ:SD18
softliQ:SD21
softliQ:SD23
Resin volume
[l]
5
7.5
9
Salt consumption per full regeneration
[kg]
0.15 - 0.55
0.20 - 0.80
0.23 - 0.95
Max. capacity of brine tank
[kg]
35
Salt consumption
per m³ and °dH
per m³ and °f
per m³ and mol
[kg/m³ x °dH]
[kg/m³ x °f]
[kg/mol]
0.025 - 0.040
0.014 - 0.022
0.140 - 0.221
Max. flushing water flow
[m³/h]
0.3
0.4
0.6
Total waste water volume per full regeneration
[l]
21 - 31
28 - 43
32 - 51
Waste water volume
per m³ and °dH (complete regeneration)
per m³ and °f (complete regeneration)
per m³ and mol (complete regeneration)
[l/m³ x °dH]
[l/m³ x °f]
[l/mol]
3.5 - 2.2
1.9 - 1.2
19 - 12
General data
softliQ:SD18
softliQ:SD21
softliQ:SD23
Suitable for homes of ... families (up to ... people)
1 - 2 (4)
1 - 4 (9)
1 - 5 (12)
Water temperature
[°C]
5
– 30
Ambient temperature (drinking water)
[°C]
5
– 25
Ambient temperature (technical application)
[°C]
5
– 40
Max. humidity of air (non-condensing)
[%]
90
DVGW registration number
DW-9151CT0491
SVGW registration number
test pending
Order no.
189 100
189 200
189 300
Содержание softliQ:SD Series