Operation
50 | 80
B
A
_
T
D3
-B
S
0
0
1
e
n
_
0
1
4
_
so
ft
liQ
-SD
5.
Enter the set value in the control unit.
Menu level>Water hardness
The value is available in the Grünbeck myProduct app.
6.9
Installer level (code 005)
The settings described here may only be made by Grünbeck's technical service /
authorised service company.
Menu level>Information>Installer contact data
1.
Touch the button
.
2.
Enter the code using the numerical keypad.
3.
Confirm with
✔
» You can change the parameters and values.
The following parameters and values can be changed:
Menu items
Settings / remarks
Wi-Fi access point*
Page 1/2
Activate / deactivate
Page 2/2
IP address / SSID / password
Exchanger tank
Page 1/2
Flow [l/h]
Capacity figure [m³ x °dH]
Remaining capacity [m³]
Regeneration step
Page 2/2
Regeneration flow rate [l/h]
Last regeneration [date/time]
Above xxx [%]
Flow rates
(indication only)
Peak flow value [m³/h]
for xxxxx [min.]
Water volumes
(indication only)
Soft water [m
3
]
Make-up volume [l]
Counter readings
(indication only)
Salt consumption [kg]
Regeneration counter
Find reference position
start
Move to reference position.
Ongoing regenerations are
cancelled. After completion,
the factory setting is activated
again.