Product description
18 | 80
B
A
_
T
D3
-B
S
0
0
1
e
n
_
0
1
4
_
so
ft
liQ
-SD
3.8.2
Power circuit board (only with softliQ:SD23)
WARNING:
Fatal shock hazard.
● Contact with live parts may result in injury.
► Make sure that the product is in a voltage-free state (pull out the mains plug)
before removing the protection against accidental contact.
The power circuit board is located under the protection against accidental contact.
1.
Remove the protection against accidental contact to access the power circuit board.
Item
Description
Item
Description
1
Protection against contact
2
Fault signal contact (upper two terminals)
max. 230 V/max. 1 A
(factory setting N.C.)
3
Programmable output (lower two terminals)
e.g. connection of the regeneration water
delivery pump
max. 230 V/max. 1 A
(factory setting regeneration water delivery pump)
2.
Use the following connection cables for connection to the fault alarm contact or
the programmable output:
● Flexible cables of quality H05xx F 2x0.75 mm² or comparable, because consumers
operated with mains voltage may be connected. A larger line cross-section is
unsuitable.
3.
After the connection has been made, attach the protection against accidental
contact.