manualshive.com logo in svg
background image

EYL85066WE

EYL95066WE

EYL10566WE

WATER HEATER

USER MANUAL

Содержание EYL10566WE

Страница 1: ...EYL85066WE EYL95066WE EYL10566WE WATER HEATER USER MANUAL ...

Страница 2: ...s every time Welcome to Electrolux Visit our website to Get usage advice brochures trouble shooter service information www electrolux com Register your product for better service www electrolux com productregistration Buy Accessories Consumables and Original spare parts for your appliance www electrolux com shop 2 SAFETY INSTRUCTIONS 6 3 ELECTRICAL REQUIREMENTS 8 1 SAFETY INFORMATION 4 4 WATER REQ...

Страница 3: ...ase visit www electrolux co uk Please ensure you read the information under What to do if in your instruction booklet before contacting us for service Servicing and or installation of your product including electrical connections and water connections should be carried out by a suitably qualified engineer In the user manual and on our web site www electrolux co uk you will find some useful informa...

Страница 4: ...and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved 1 SAFETY INFORMATION 1 1 Children and vulnerable people safety 1 2 General Safety Keep all packaging away from children Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Before mai...

Страница 5: ... the fixed wiring in accordance with the wiring rules The fixed wiring insulation must be protected for example by insulating sleeving having an appropriate temperature rating The pressure relief device must be fitted during installation unless it is incorporated in the appliance The appliance must be permanently connected to fixed wiring 5 ENGLISH ...

Страница 6: ...r earth leakage trips and contactors Always switch off the power at the consumer unit and isolate the electrical supply before making any electrical connections or if you have to remove the cover of an installed unit Remove all the packaging labeling and protective film if applicable before first use Obey the installation instruction supplied with the appliance Keep the minimum distance from the o...

Страница 7: ... or if the water is leaking from the shower unit itself Turn off at the mains electrical supply and refer to the Troubleshooting section see page 23 or contact Electrolux Customer Services see page 3 Do not crush or kink the shower hose this could damage the hose cause leaks and activate the pressure relief device Contact your municipal authority for information on how to discard the appliance cor...

Страница 8: ...s advisable to contact the local electricity supply company The shower must be connected to its own independent electrical supply It must not be connected to a ring main spur power socket or lighting circuit The electrical supply must be adequate for the loading of the unit and existing circuits Check your consumer unit main fuse box has a main switch rating of 80A or above and that it has a spare...

Страница 9: ...wice the diameter of the cable or conduit Unit Rating 240V Circuit Protection Device MCB Cartridge Fuse 8 5kW 9 5kW 10 5kW 40A 45A 40 45A 45A 45A 45A Cable current carrying capacity table for twin and earth PVC insulated cable Current carrying capacity In an insulated wall In conduit or trunking Clipped direct or buried in a non insulated wall 6mm 32A 6mm 38A 6mm 46A 10mm 43A 10mm 52A 10mm 63A Not...

Страница 10: ...hower tray within the 25mm limit then a double check valve or similar It is required that the showerhead be so that it can only discharge water at a point not less than 25mm above the spill over level of the relevant bath shower tray or other If the shower is to be installed in a hard water area we recommend that an in line scale the shower Please refer to your supplier for advice The shower must ...

Страница 11: ...cess cover screws Position the unit where it will NOT be in direct contact with water from the showerhead Position the shower unit vertically The shower should be 1m minimum height from floor Take the proper water and cable entry position into consider while selecting the installation position See Fig 1 for the water and cable entry position options Fig 1 Before installation make sure you read thr...

Страница 12: ...t from the wall Using the installation template supplied mark the positions of the three fixing holes To mark the drilling position Check if there is any buried pipes or cables before drilling CAUTION NOTE Ensure that there are sufficient lengths of supply pipe and electrical cable to reach the connection points as shown on the template Remove the installation template and drill the fixing holes d...

Страница 13: ... block Fig 4 5 2 Plumbing connection To remove the front cover Hook the backplate over the top screw and DO NOT fully tighten the screws at this stage Unscrew the screws that fixing the front cover Fig 2a and pull out the front cover lightly then disconnect the cable between front cover and the chassis Fig 2b after that remove the front cover Fig 2a Fig 2b NOTE The knobs and On off button are fixe...

Страница 14: ...connection to the shower NOTE thr At this stage no water can flow ough the unit To check the water supply leak NOTE through to It is essential that all pipe work is flushed remove debris and swarf that could otherwise damage the unit 21mm Fig 5 14 www electrolux com This Electrolux shower heater has 2 wiring terminals and 2 earthing terminals shown as Fig 6 You can choose the proper terminals when...

Страница 15: ... to the shower tighten the 3 screws to fix the shower on the wall firmly 4 Check to ensure that the wiring is not trapped and replace the cover squarely to the backplate and guide into position so that the knobs locate correctly into the splined the points above 5 While applying slight pressure to the cover secure in position with the retaining screws 6 Once you place the front cover on the the 4 ...

Страница 16: ...ter in the vertical direction with 425 1mm distance Fig 9 1 NOTE proper position for the bracket if necessary Put the wall plugs on the holes then remove the sliding rail holder covers from sliding rail holders on the upper position then replace the sliding rail holder cover 3 Check if there is any buried pipes or cables before drilling WARNING NOTE point the opening downward see Fig 10 Sliding Se...

Страница 17: ...rotate increase water On off button Control the shower unit s electricity and working start stop when push on stops NOTE When you press the On off button the showerhead To avoid too hot or too point directly to human body 6 1 Product features 3 4 2 3 1 Temperature 4 2 Heating power selector This section is used to select the desired working power of the shower The shower have 4 different working p...

Страница 18: ...turn on the electric supply to the shower at the isolating switch CAUTION Failure to turn the control to the the PRD Pressure Relief Device to operate CAUTION Fig 15 Fig 14 Temperature Pass the COLD button to choose the cold setting Turn the temperature knob fully clockwise to MINIMUM flow 6 When a smooth flow of water is obtained rotate the temperature control from MINIMUM to MAXIMUM several time...

Страница 19: ... will take a few seconds for the temperature to stabilise after changing the Heating power knob position The water temperature is altered by the water through the shower via the temperature control After obtaining your showering temperature the knob can be left as the normal setting and should only need altering to compensate for seasonal changes in ambient water temperature Turn the temperature c...

Страница 20: ...age Setting Concentrated spray impact with pulse effects suitable for part pulse massage on muscle Shower spray with massage feeling Have a broader area suitable for large area shower plus spray water 6 4 Shower head setting 20 www electrolux com ...

Страница 21: ...front panel Do not use a chemically treated cloth or duster to clean the unit Do not use benzine thinner polishing powder or similar solvents for cleaning These may cause the plastic surface to crack or deform WARNING 7 1 General cleaning 7 2 Before maintenance work you must switch off the power at the isolating switch Do not remove the front panel Make sure that the sealing O ring is in place rea...

Страница 22: ...is in malfunction Below table show what the error code mean This product cannot afford very high external water pressure for safety use and usage life reasons highest limitation is 6 9 bar and PRD as product s pressure relief device when external factors like handset block happens and causes heater can not stand the internal pressure reaches the highest limit PRD will break up to release water pre...

Страница 23: ...cal malfunction Safety cut out operated Blocked showerhead clean or replace blocked sprayplate in showerhead Check if stop valves are fully open Check See Water too hot causes and their appropriate action cures If it continues contact Electrolux Customer Service select higher power electrician or contact Electrolux Customer Service Thermal safety cut out device has operated Have the unit checked b...

Страница 24: ...ube Shower fails to shut off Blocked showerhead shower hose Showerhead not removed while commissioning Faulty start stop switch Debris in the solenoid Check for free passage through hose Replace the hose if necessary and Fit new PRD Commission unit with showerhead removed Replace start stop switch Replace solenoid valve NOTE follow the commissioning procedure It is advised all electrical maintenan...

Страница 25: ...5519W17171 000 001 www electrolux com shop ...

Отзывы: