9.
TROUBLESHOOTING
Problem/Symptom
Cause
Action/Cure
Shower varies from
normal temperature
to cold during use.
Water pressure has
dropped below minimum
required.
Wait until the water pressure resumes to
normal.
Clean or replace blocked sprayplate in
Pressure relief device
has operated (water
ejected from PRD
tube).
Shower fails to
shut off.
Blocked showerhead.
shower hose.
Showerhead not removed
while commissioning.
Faulty start/stop switch.
Debris in the solenoid.
Check for free passage through hose.
Replace the hose if necessary and
Fit new PRD. Commission unit with
showerhead removed.
Replace start/stop switch.
Replace solenoid valve.
NOTE:
follow the commissioning procedure.
It is advised all electrical maintenance/repairs to the shower should be carried out by
contact Customer Service for advice.