background image

Heat Pump Hot Water System

User Manual

Содержание Heat Pump Hot Water System

Страница 1: ...Heat Pump Hot Water System User Manual ...

Страница 2: ...Care Centre environmental tips Information on disposal for users Most of the packing materials are recyclable Please dispose of those materials through your local recycling depot or by placing them in appropriate collection containers If you wish to discard this hot water system please contact your local authorities and ask for the correct method of disposal caution Contact an authorised installer...

Страница 3: ...s When the heat pump hot water system is installed with an additional off peak power supply the power supply must not be standard off peak also known as off peak 1 available only 8 hours The off peak power supply must be changed to or kept as extended off peak also known as off peak 2 available up to 18 hours If extended off peak is not available the heat pump hot water system is to be connected t...

Страница 4: ...ng delivered must not exceed 50 C at any outlets used primarily for purposes of personal hygiene To comply with these standards a tempering valve set must be fitted to the hot water system Do not use this hot water system if it has at any stage been immersed in water Immediately call a licensed plumber gas fitter or authorised technician to inspect and or service the system Do not disconnect the e...

Страница 5: ...power supply Hot Water System Model Number for STC registration Serial numbers Installation date Installed by Notes Information required to claim your STCs System type System model no Description Heat Pump KHPE270362A C Kelvinator Heat Pump 270L tank continuous KHPE270362A OP2 Kelvinator Heat Pump 270L tank off peak 2 and continuous tarrif KHPE340362A C Kelvinator Heat Pump 340L tank continuous ta...

Страница 6: ...the primary heating device and employs the same heating technology as a refrigeration style air conditioner It absorbs heat energy from the surrounding air and transfers it into water circulating between the heat pump and the storage tank Since this heat energy isn t created but simply moved and concentrated from one location to another it is very efficient and cost effective especially compared t...

Страница 7: ...er quality Water quality can vary in different locations and affect the performance and safe operation of the hot water system If the water supply is not within the acceptable limits as indicated below the hot water system should not be installed and will not be covered by warranty from the manufacturer A suitable solution is to implement a water pre treatment process to bring the water quality to...

Страница 8: ...elief valve returning it to its normal position 10 Reconnect the inlet piping to the storage tank and then turn on the isolation valve located on the inlet piping to allow mains water to refill the tank 11 Turn on the nearest hot water tap to allow air to be expelled from the system Once water has begun to flow freely from the tap for a period of time and all air has been expelled from the system ...

Страница 9: ... other appliance During this procedure there must be no smoking open flame or any electrical appliance operating nearby If hydrogen is discharged through the tap it will probably make an unusual sound as with air escaping 12 Clean all filters in the hot water system including any that may be located on individual fixtures as they may have become blocked by debris during the process of flushing and...

Страница 10: ... t been on for long it will take some time for the temperature inside the tank to get to its set point level If the heat pump is working correctly the output connection on the heat pump should be warm indicating that it is pumping warm water into the tank If the tank element is installed on off peak check with your power provider that you are on extended off peak or off peak 2 tarrif This applianc...

Страница 11: ...ransported at the owner s cost and risk while in transit to and from Electrolux or its ASC 6 Proof of purchase is required before you can make a claim under this warranty 7 You may not make a claim under this warranty unless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged ...

Страница 12: ...er information about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...

Отзывы: