2.2 Integration of a flushing compressor in piping in place of, for example, an adjusting
piece
For this connection type, the parts for the nominal widths 1", 1 ¼", 1
½" and 2" are included in the connection fitting cases ¾" - 2".
The installation length of these fittings is variable and in conjunction
with the connection bracket they can be used as of an installation
length of approx. 175 mm.
As of an installation length of approx. 300 mm, connection is possible
without a bracket.
With shorter distances, installation with a connection bracket
(e.g., in place of a 1" and 1¼" adjusting piece with 190 mm).
Replace the on-site adjusting piece with adapters and brackets and
integrate the flushing compressor with connection tubes.
Fig. D-4: Installation example of a flushing compressor with connection bracket