7. Raise the boom to 60° or higher. The system will display the configuration has been relocated at
a high boom angle.
8. Press the
Calibrate
button then measure and enter the high angle radius in feet and tenths of a
foot. Press the
Exit
button and the measurement will be stored.
9. Next move the boom back to a position above 65° and fully extend. Pressing the calibrate
button again will prompt for a high angle radius. Enter the radius in feet and tenths. Pressing the
exit button will store the measurement and allow for the last measurement which is low angle.
10. Lower the boom to the lowest angle allowing the system to display a maximum capacity. Press
the
Calibrate
button and enter the low angle radius in feet and tenths of a foot. Press the
Exit
button.
11. The screen will display
“Finish Calibrating Attachment?”
Press the
Calibrate
button to save
the jib calibration in the system.
12. Press
Exit
to return to the normal operation mode. The system should display the proper radius
and hook load. This is a sign that the jib calibration was successful.
NOTE: This procedure must be completed for each jib configuration. This includes angle offsets as well
as jib extensions.