21
W450769A 01/14
2.5.1 Calibration Menus
00 Error codes –
Displays system information and error codes.
01 Crane Data –
Used to reset and backup the crane personality data.
02 Dimensions –
Used to enter the crane geometry dimensions previously recorded.
03 Extension Sensor –
Used to set the zero point and span of the extension sensor.
04 Angle Sensor –
Used to set the zero point and span point for the angle sensor.
05 Swing Potentiometer –
Used to set the zero point and direction for the swing potentiometer.
06 Pressure –
Used to calibrate the lift cylinder dimensions and load.
07 Radius/Moment –
Used to calibrate the radius and moment for the main boom.
08 Boom Deflection –
Used to calibrate deflection for the main boom and attachments.
09 Compensation –
Sets rod side pressure compensation when booming down.
10 Erected Attachments –
Used to calibrate the radii, moments, and dimensions of erected
attachments.
11 Auxiliary Head –
Used to enter the dimensions of the auxiliary head.
12 Stowed Attachments –
Used to enable or disable stowed attachments.
13 Digital Inputs –
Used to view the status of digital inputs.
14 Enable Attachments –
Used to enable or disable attachments in the system.
15 Enable Winches –
Used to enable or disable winches in the system
16 Data Retrieval –
Used to view radius moment, attachments, and pressure data as needed.
17 Language –
Used to set the language for main display.
With the desired menu displayed, press the key adjacent to the menu name to select.
18 Not Used
19 Outrigger Sensing
- Not Used