50
W450769A 01/14
3.3.4 Group “D” Fault Codes
Group “D” fault codes represent faults detected for capacity chart selection.
The following chart details all the available codes in the left column and the actions to take in the right
column.
FAULT
CODE
WRONG
SWING
AREA
WRONG
BOOM
LENGTH
CHART
NOT
FOUND
ACTION
000
No Fault Found
NONE
001
X
Check other sensor faults first,
Re-select CRANE SETUP
002
X
Boom length is out of range for selected chart.
Check crane setup, boom length and extension.
003
X
X
Check other sensor faults first,
Re-select CRANE SETUP
004
X
Swing to correct working area to select chart.
Check swing sensor zero position.
Follow SECTION 3.10.4
005
X
X
Swing to correct working area to select chart.
Check swing sensor zero position.
Follow SECTION 3.10.4
006
X
X
Check other sensor faults first,
Re-select CRANE SETUP
007
X
X
X
Check other sensor faults first,
Re-select CRANE SETUP