Menu 10 – Calibrating Erected Attachments
NOTE: When an “Uncalibrated Jib Attachment” is erected there will be a warning at the bottom of the
information screen that reads “WARNING – JIB NOT CAL’D”.
1. Erect the jib attachment to be calibrated in the operator set up and set the pick point. Once the
setup is completed, enter the calibration menu and press the
Menu Up
button until
“10 Erected
Attachments”
is displayed.
2. Press the
10 Erected Attachments
button to access the menu asking to input the main hook
weight.
NOTE: Do not have a hook weight on the main boom while calibrating the jib, however, if this is
unavoidable you must enter this hook weight. If the main hook weight has been removed, enter 0.00.
3. Press the
Exit
button to access the menu asking for the fly hook weight. Enter the fly hook
weight and press the
Exit
button and the system will take you to the calibrate screen.
4. The system will store the jib configuration and the configuration of the boom at the time of
calibration.
5. In the example, the system shows the boom was
“Telescoped in at a Low Angle”
.
6. Press the
Calibrate
button and the system will ask for the corrected radius for this configuration.
Measure the current radius and enter in feet and tenths of a foot. Press the
Exit
button.