13
W450769A 01/14
2.2 The MicroGuard 510 Display
2.2.1 Command Entry
The buttons that are identified as
A
,
B
,
C
, and
D
will be used most for the procedures described in this
document and their function will vary depending on the routine being performed. Commands for each
routine will show in the information window as text adjacent to the buttons. Follow directions for each
routine carefully.
2.2.2 Number Entry
The display does not have a numerical keypad so when numbers are required, the display will change
to enable number entry.
Use the
B
and
D
buttons scroll left and right. The “cursor” will appear as flashing < > brackets on
either side of the number. Use the
A
button to enter the number. Use the
C
button to exit the number
entry subroutine.
As each number is selected, press Button
A
to enter it into the system. The number will then appear in
the [ ] brackets (125.00 in this example). Up to five numbers may be entered. When entering a negative
value, enter the numbers and decimal first, then enter the minus sign. When all digits are correct, press
button
C
to enter the complete number.
Example: To enter the value “-2.98”:
1. Press button
B
or
D
until the number “2” is selected (indicated by flashing < > brackets) and
then press button
A
to enter the number.
NOTE: If a number is entered incorrectly, select the backspace “<” and press button A.
TEST
SET
A
B
C
D
TEST
SET
A
B
C
D