CAUTION
Charging recommendations
•
Lithium Modules do not develop a memory and need
not be fully discharged before recharging.
•
Batteries left uncharged will slowly discharge. Before
initial use each spring season, be sure batteries have a
full charge before mowing.
•
If charger is not left plugged in, the batteries should be
fully charged every 30 days to maintain battery life.
Never allow charger to charge more than 15 hours.
•
When charging, be sure charger cooling fan inlet and
outlet are not blocked.
9.3.3
CHARGE THE BATTERY
WARNING
More details of charger are referred to in the charger
manual. Read and understand all its safety warnings and
instructions. Failure to follow them may result in electrical
shock, fire and/or serious injury.
1. Turn the ignition power switch to the “OFF” position.
2. Remove the key and make sure the machine comes to a
complete stop.
3. Remove the dust cap from the battery charging port on
the mower.
4. Plug the charger into the port.
5. Plug other end of charger into household GFCI protected
outlet.
WARNING
Always turn charger “OFF” before disconnecting charger
from mower. Disconnect charger cord from wall outlet.
WARNING
Cover the battery charging port with the dust cap before
operation.
9.3.4
REPLACE THE BATTERY
9.3.4.1 DISCONNECTING THE BATTERIES
(LITHIUM MODULES)
WARNING
Only Greenworks Commercial dealer or authorized service
center can disconnect the battery.
WARNING
The battery connectors are located under the battery cover.
ALWAYS disconnect battery cables by pulling inward on
RED battery quick disconnect handle in battery box
compartment before ANY maintenance is performed on
mower unit.
WARNING
Can only be operated by distributor!
1. Open battery compartment and lift up battery cover to
expose Lithium Modules.
2. Grasp RED BATTERY QUICK DISCONNECT
HANDLE by wall of mower.
3. Pull INWARD on lever until disengaged from wall plug.
4. Unplug all red battery connectors by grasping each red
plug and pull apart.
WARNING
DO NOT PULL ON BATTERY CABLES!! ONLY pull
on connectors!!
5. Battery may be removed (if needed) by lifting Lithium
Module by silver handle on top of each battery case.
9.3.4.2 RECONNECTING THE BATTERIES
(LITHIUM MODULES)
WARNING
Only Greenworks Commercial dealer or authorized service
center can connect the battery.
1. Open battery compartment and lift up battery cover to
expose Lithium Modules.
2. Grasp RED BATTERY QUICK DISCONNECT
HANDLE by wall of mower.
3. Push lever OUTWARD into battery compartment wall
plug until “CLICK” is heard with complete connection.
Take unused battery connector to plug into the next
battery. Continue connecting batteries in a line until ALL
batteries are connected to each other and ONLY one
connector is left. The last unused connector can be used
to plug into the internal charging port for charging the
battery.
4. Close battery compartment lid and turn lever to close.
5. Mower is ready for use.
9.4
DIGITAL DISPLAY
The function of the digital display, located on the control
panel, is to provide electrical system information to the
operator. It gives detailed information in the form of
pattern,codes and number.
15
English
EN
P0802464-00 v1.2