background image

A/B

4.1

Throttle Wiper High

Throttle failure

1. See Monitor menu » Inputs: Throttle Pot.
2. Throttle pot wiper voltage too high.
3. Bring throttle pot wiper voltage below the

fault threshold.

A/B

4.2

Throttle Wiper Low

Throttle failure

1. See Monitor menu » Inputs: Throttle Pot.
2. Throttle pot wiper voltage too low.
3. Bring throttle pot wiper voltage above the

fault threshold.

A/B

4.3

Pot2 Wiper High

Throttle failure

1. See Monitor menu » Inputs: Pot2 Raw.
2. Pot2 wiper voltage too high.
3. Bring Pot2 wiper voltage below the fault

threshold.

A/B

4.4

Pot2 Wiper Low

Throttle failure

1. See Monitor menu » Inputs: Pot2 Raw.
2. Pot2 wiper voltage too low.
3. Bring Pot2 wiper voltage above the fault

threshold.

A/B

4.5

Pot Low Overcurrent

Throttle failure

1. See Monitor menu » Outputs: Pot Low.
2. Combined pot resistance connected to pot

low is too low.

A/B

4.6

EEPROM Failure

Download the correct software

(OS) and matching parameter

default settings into the control-

ler and cycle KSI.

Download the correct software (OS) and match-

ing parameter default settings into the controller

and cycle KSI.

A/B

4.7

HPD/Sequencing Fault Reapply input s in correct 

sequence.

1. KSI, interlock, direction, and throttle inputs

applied in incorrect sequence.

2. Faulty wiring, crimps, or switches at KSI, 

interlock, direction, or throttle inputs.

3. See Monitor menu » Inputs.

A/B

4.7

Emer Rev HPD

Reapply input s in correct 

sequence.

At the conclusion of Emergency Reverse, the

fault was set because various inputs were not 

returned to neutral. If EMR_Interlock = On, clear

the interlock, throttle, and direction inputs. If

EMR_Interlock = Off, clear the throttle and 

direction inputs.

A/B

4.9

Parameter Change Fault Cycle KSI.

This is a safety fault caused by a change in 

certain parameter settings so that the vehicle will 

not operate until KSI is cycled.

A/B

5.2

Slave PDO Fault

Cycle KSI

Time between CAN PDO messages (between

Master controller and Slave controller) received

exceeded the PDO Timeout Period.Check the

communcation wires from slave controller.

A/B

5.3

Master or Slave HPD

Fault

Reapply inputs in correct 

sequence.

1. KSI, park switches ,PTO switch and throttle 

inputs applied in incorrect sequence.
2. Faulty wiring, crimps, or switches at KSI, park

switches and throttle inputs.

A/B

5.4

Battery BMS Fault

Check the battery voltage , If

battery is low, recharge; Restart

vehicle; Replace battery and

contact dealer

Check the battery voltage , If battery is low, 

recharge; Restart vehicle; Replace battery and 

contact dealer.

19

English

EN

P0802464-00 v1.2

Содержание CZ52R

Страница 1: ...CZ52R CZ60R PZ52R PZ60 R EN OPERATOR MANUAL FR MANUEL D OP RATEUR Zero Turn Mower Zero Turn Mower ES MANUAL DEL OPERADOR Zero Turn Mower www GreenworksCommercial com...

Страница 2: ...system information 14 9 3 Battery and charger 14 9 4 Digital display 15 9 5 Faults 16 10 Fault code For CZ series 17 11 Fault code For PZ series 24 12 Maintenance 30 12 1 Mower blade maintenance 30 1...

Страница 3: ...slightly in detail Greenworks Commercial Products reserves the right to redesign and change the machine as deemed necessary without notification If a change has been made to your machine which is not...

Страница 4: ...njury while operating or performing any adjustment or repair See ANSI Z87 1 Do not operate machine unless discharge guard or other safety devices are in place and working Always wear a face mask or a...

Страница 5: ...ome to a complete stop before cleaning the machine or unclogging the discharge guard If lawnmower strikes a foreign objects stop the machine rotate the ignition switch to OFF position then if it is sa...

Страница 6: ...rs and do not expose to rainwater Avoid storing in direct sunshine Do not charge batteries in rain or in wet location Double insulation When servicing use only identical replacement parts Only to be u...

Страница 7: ...cy cycles per sec ond W Watt Power min Minutes Time min Per Minute Revolutions strokes sur face speed orbits etc per minute Direct Current Type or a characteristic of current no No Load Speed Rotation...

Страница 8: ...d electrolytes are corrosive and toxic DO NOT get the solution in the eyes or on skin and do not swallow it DO NOT put these batteries in your regular household trash DO NOT incinerate DO NOT put them...

Страница 9: ...und objects buildings and other obstacles NOTE Get comfortable with mower before us ing High Speed setting The maxi mum speed may be adjusted at any time whether the mower is in motion or not 20 ON OF...

Страница 10: ...Do not operate the mower with the ROPS folded lowered position a standard operating mode A folded ROPS does not provide rollover protection WARNING Always wear your seat belt unless the ROPS is folded...

Страница 11: ...ted forward and rearward by moving the latch under the seat Move the latch to left and pull the seat where you have the best control of the machine and are the most comfortable and then tighten the sa...

Страница 12: ...control levers rearward an equal distance To turn left move the right steering control lever farther forward from neutral than the left steering control lever To turn right move the left steering cont...

Страница 13: ...wn from the equipment Approach at a slow speed and angle one drive wheel at the obstruction Continue at an angle until the wheel clears and then pivot the opposite wheel around When turning on soft we...

Страница 14: ...ace the steering control levers in the park brake position turn the key to the OFF position and get help Never make sudden starts stops turns or reverse direction especially when maneuvering on slopes...

Страница 15: ...allow flames sparks or smoking near batteries Keep batteries out of reach of children Always keep protective shields covers and guards in place and securely fastened If they become damaged repair or...

Страница 16: ...ALWAYS disconnect battery cables by pulling inward on RED battery quick disconnect handle in battery box compartment before ANY maintenance is performed on mower unit WARNING Can only be operated by d...

Страница 17: ...ing capacity 2 time signal 3 controller fault battery fault motor fault 4 fault position 5 fault code total working hours 9 5 FAULTS The Canbus system will take action to protect the user and machine...

Страница 18: ...limit with FET bridge enabled A B 1 8 Severe Overvoltage Check battery wires and connections Check fuse state and main contact connections Capacitor bank voltage exceeded the Severe Overvoltage limit...

Страница 19: ...or Enable should be programmed Off 3 See Monitor menu Motor Temperature and Inputs Analog2 A B 3 1 Main Open Short Open or short on driver load 1 Open or short on driver load A B 3 2 Coil2 Driver Open...

Страница 20: ...lock direction and throttle inputs applied in incorrect sequence 2 Faulty wiring crimps or switches at KSI interlock direction or throttle inputs 3 See Monitor menu Inputs A B 4 7 Emer Rev HPD Reapply...

Страница 21: ...ternal supply current within range 1 External load on the 5V and 12V supplies draws either too much or too little current 2 Fault Checking Menu parameters Ext Supply Max and Ext Supply Min are mistune...

Страница 22: ...the battery with the PC software 2 Restart vehicle 3 Replace battery and contact dealer BMS 1 6 Battery Serious Insula tion Alarm Fault 1 Cycle KSI 2 Replace battery and contact dealer 1 Check the ba...

Страница 23: ...en braking R M L 1 4 CONTROLLER SEVERE OVERTEMP If machine is operating under heavy load reduce load with lower speed blade until temperature cools down Bring heatsink temperature below 85 C and cycle...

Страница 24: ...UMP SRO The lift switch is turned on before KSI The lift switch is turned on before KSI R M L 3 5 VALVE DRIVER FAULT Valve driver is either open or shorted Valve driver is either open or shorted R M L...

Страница 25: ...use state and main contact connections 1 Check the Battery parameters 2 Check the connections 3 Check the KSI or B fuse TR TL 18 Severe Overvoltage Cycle KSI Bring capacitor voltage below Severe Overv...

Страница 26: ...connected properly 2 If the application doesn t use a motor ther mistor Motor Temp Sensor Enable should be programmed Off 3 See Monitor menu Motor Temperature and Inputs Analog2 TR TL 31 Main Open Sho...

Страница 27: ...he connections of Electric Putter 1 See Monitor menu Inputs Pot2 Raw 2 Pot2 wiper voltage too high 3 Bring Pot2 wiper voltage below the fault threshold TR TL 44 Pot2 Wiper Low 1 Electric Putter Electr...

Страница 28: ...tion Fault Check mower controller com munication connections Re place mower controller Time between CAN PDO messages between Master controller and Mowers received exceeded the PDO Timeout Period Check...

Страница 29: ...l Model Number Download appropriate software for your controller model Download appropriate software for your control ler model TR TL 99 Dualmotor Parameter Mismatch BMS 11 Battery OverTemp Alarm Faul...

Страница 30: ...S 27 Battery OverCurrent Stop Fault 1 Cycle KSI 2 Replace battery and contact dealer 1 Check the battery with the PC software 2 Restart vehicle 3 Replace battery and contact dealer BMS 28 Hardware Fau...

Страница 31: ...Menu parameters are mis tuned 3 If the application doesn t use a motor thermistor Temp Compensation and Temp Cutback should be programmed Off ML M M MR 24 PRE CHARGE_FAILED 1 Cycle KSI 1 Cycle KSI 2...

Страница 32: ...de position the blade with the cutting edges toward the ground Assemble the bolt Using a socket or wrench turn the blade nut CLOCKWISE in order to secure the blade 12 1 2 INSTALL THE BLADE 1 Place the...

Страница 33: ...ires Replace defective cords and wires immediately 12 8 LITHIUM ENERGY MODULE MAINTENANCE In order to prolong the battery module life cycle and make sure the module stays in good condition please adhe...

Страница 34: ...eration regularly Turn the key to the OFF position before unclogging the discharge chute Never clear the discharge chute with the machine running Turn the key to the OFF position and be sure the blade...

Страница 35: ...e sure batter ies are charged Circuit breakers are tripped Check to see that ALL cir cuit breakers are not tripped Deck System Resistance Test Procedure Make sure your Digital Multimeter is capable of...

Страница 36: ...istance between pin 2 and pins 1 4 5 and 6 should be 0 ohms If resistances are above or below these ranges the deck motor will need to be replaced Repeat the process for the other motor as needed 10 I...

Страница 37: ...1 WHAT IS COVERED BY THIS WARRANTY Greenworks Commercial Products makes the following warranty to the original purchaser only A Residential Use Greenworks Commercial Mowers used for normal residentia...

Страница 38: ...mance or durability of the equipment Mowers that have had their serial number removed or made illegible Depreciation or damage caused by normal wear lack of reasonable and proper maintenance failureto...

Страница 39: ...17 SLOPE GUIDE Use this diagram when determining the degree of slope to be mowed English EN 38 P0802464 00 v1 2...

Отзывы: