50
309085
Dual Ram Cross-Over Control Function
X-Over Factory Setup
The FACTORY SETUP option within the X-OVER
CONFIGURATION screen is typically available for
factory use only. This can be useful however if a
243254 Cross-Over module is replaced or the commu-
nication module within the control box has been re-
placed. The FACTORY SETUP option will show the
following screen. This function initializes the cross-
over control box that is mounted to the side of the
main control box. Initializing the cross-over box is to
configure the cross-over box for the right communica-
tion setup and assign the proper address associated
with UNLOADER A or UNLOADER B. This is done at
the factory when a dual ram cross-over system is
ordered. When F1 or F5 is pressed, the operator will
be prompted to ensure the communication cables to
UNLOADER A or UNLOADER B cross-over control
box is the
ONLY one connected. When ready, the
operator will be prompted to continue, the pendant will
search for a cross-over control box and initialize it as
the appropriate UNLOADER module, A or B.
To access this screen, from the MAIN screen, F5
(SETUP), enter the correct PASSWORD, acknowledge
the correct zones are configured, proceed to the
CONFIGURE X-OVER selection, then press B.
I N I T
I N I T
U N L O A D E R
U N L O A D E R
X – O V E R
X – O V E R
> A <
E X I T
> B <
F1
F2
F3
F4
F5
This function must be used for a customer that had (2)
Therm-O-Flow Plus unloader assemblies and later
adds the cross-over modules themselves. This opera-
tion would be required to initialize each unloader so the
cross-over controls and the pendant know which
cross-over is related to which module.
Содержание Therm-O-Flow Plus
Страница 22: ...22 309085 Notes...
Страница 28: ...28 309085 Advanced Pendant Control Screen Map TI0683 See Next Page...
Страница 30: ...30 309085 Notes...
Страница 43: ...43 309085 Notes...
Страница 60: ...60 309085 Service For 400 480 and 575 VAC Supply Units Junction Box Schematic Fig 18 TI0673...
Страница 61: ...61 309085 Service For 240 VAC Supply Units Junction Box Schematic Fig 19 TI0673...
Страница 65: ...65 309085 Notes...