Advanced Pendant Control
Zone Setup/PID Type Selection
Each zone must be setup within the pendant. The
pendant must know if the zone is ACTIVE or UN-
USED. If ACTIVE, the pendant must know what type
of Graco heat device is connected so the proper PID
values can be loaded to the zone temperature control-
ler. Each zone can be named as needed, to help
differentiate the devices connected to the hot melt
system.
Access the ZONE SETUP/PID screen through the
SETUP selection, enter the correct PASSWORD,
acknowledge the proper amount of zones are config-
ured and proceed to the following screen.
1 = R E C I P E S / T E M P S
3 = Z O N E
S E T U P / P I D
4 = P A S S W O R D
C H A N G E
Z N –
O F F
E X I T
C H G
Z N +
F1
F2
F3
F4
F5
Press 3 on the numeric keypad and the ZONE SET-
UP/PID screen is displayed.
A C T I V E
Z O N E # 0 1
N A M E : Z O N E
#
P I D
T Y P E : P L A T E
Z N –
O F F
E X I T
C H G
Z N +
F1
F2
F3
F4
F5
This screen shows the status of the zone, ACTIVE or
UNUSED, the zone NAME and the PID TYPE. Press
the F1 (ZN–) and F5 (ZN+) keys to toggle through the
zones. Pressing F2 will turn the zone to UNUSED if
active or turn the zone to ACTIVE if unused. Turn the
status to ACTIVE if a heat device is connected to the
zone. Turn to UNUSED if nothing is connected to the
zone. Pressing F4 (CHG) will change the F–Key
selections to allow editing of the zone NAME or toggle
through the available PID types.
The following screen is displayed when F4 (CHG) is
pressed.
> A C T I V E > E D I T < Z O N E # x x
N A M E : Z O N E
#
P I D
T Y P E : P L A T E
P I D +
D O N E
N A M E
F1
F2
F3
F4
F5
Pressing F5 (NAME) will clear the zone name and
allow the user to enter any name needed. Press F3
and then ENTER on the keypad when done entering
the new name.
Pressing F1 (PID+) will toggle through the available
PID zone types available. The following PID types will
show after PID TYPE: when F1 (PID+) is pressed.
Type
P
I
d
Ram Plate
41
118
29
Pump
50
1186
296
Hose
9.9
51
12
Gun
75
49
12
Manifold
24.1
144
36
Compensator
40.9
87
21
Header
1.7
109
16
Regulator
58.5
330
82
When done selecting the appropriate PID type con-
nected to the zone, press F3 (DONE). If the PID
TYPE was changed, the appropriate PID settings are
immediately sent to the zone. The PID values are not
editable and are fixed within the pendant. If different
settings are required from those listed above, they will
need to be entered manually into the zone temperature
controller.
When pressing F3 (DONE), the screen will return to
the previous view screen. EXIT back to the MAIN
menu when done.
Содержание Therm-O-Flow Plus
Страница 22: ...22 309085 Notes...
Страница 28: ...28 309085 Advanced Pendant Control Screen Map TI0683 See Next Page...
Страница 30: ...30 309085 Notes...
Страница 43: ...43 309085 Notes...
Страница 60: ...60 309085 Service For 400 480 and 575 VAC Supply Units Junction Box Schematic Fig 18 TI0673...
Страница 61: ...61 309085 Service For 240 VAC Supply Units Junction Box Schematic Fig 19 TI0673...
Страница 65: ...65 309085 Notes...