Advanced Pendant Control
Recipe Functions
A recipe is a series of SV temperatures for all temper-
ature zones on the system. Once a recipe is setup,
one push of a key on the pendant will automatically
change the SV temperatures on the system to the
desired value. One recipe is called SETBACK. A
typical use is to set all the SV of the zones on the
system for recipe SETBACK to 250
F (example).
When production is to stop for awhile, the SETBACK
recipe can be sent automatically, setting all the active
zones back to 250
F. Each individual zone can have
it’s own unique temperature setting within a recipe.
RECIPE #1 and RECIPE #2 are the two other recipes
you can set up for sending SV temperatures to zones
automatically. For example, RECIPE #1 could be set
for the operating temperature of the hot melt material.
Once production resumes, RECIPE #1 can be sent to
the temperature controllers, automatically setting all
the active zones to the running temperature.
To VIEW the recipe functions while in the MAIN menu
screen, press F1 (VIEW) to proceed to the view
screens, as shown.
Pressing 1 on the key pad will access the VIEW–
SEND RECIPE screen shown.
1 = V I E W – S E N D
R E C I P E
2 = T I M E R
S E T T I N G S
3 = C R O S S – O V E R
Z O N E S
E X I T
F1
F2
F3
F4
F5
The SETBACK recipe is the first recipe shown. It
shows the SV temperature zone #1 is 250
F. Viewing
the SV temperature for the remaining zones is done by
pressing F2 (ZN+). This increments the zone dis-
played to the next configured zone. When the last
zone is reached, it returns back zone #1. To view
RECIPE #1 and RECIPE #2, press the F1 (PRV) or F5
(NXT) keys as needed. Pressing F3 (EXIT) returns
back to the MAIN SCREEN. To SEND a recipe to all
the active zones on the system, press F4 (SND). This
will send the recipe shown on the screen. All the
zones will automatically receive the SV temperature
settings for each zones of the recipe. If a communica-
tion error is encountered, the zone number is displayed
and proper action must be taken to determine why
communication to that particular zone is lost.
S E T B A C K
0 1
Z O N E
#
0 1
S V : 2 5 0 F
Z O N E ^ ^
P R V
Z N +
E X I T
S N D
N X T
F1
F2
F3
F4
F5
Содержание Therm-O-Flow Plus
Страница 22: ...22 309085 Notes...
Страница 28: ...28 309085 Advanced Pendant Control Screen Map TI0683 See Next Page...
Страница 30: ...30 309085 Notes...
Страница 43: ...43 309085 Notes...
Страница 60: ...60 309085 Service For 400 480 and 575 VAC Supply Units Junction Box Schematic Fig 18 TI0673...
Страница 61: ...61 309085 Service For 240 VAC Supply Units Junction Box Schematic Fig 19 TI0673...
Страница 65: ...65 309085 Notes...