Advanced Pendant Control
Operation of Pendant
Operate the pendant by pressing the proper keys
when prompted. The pendant contains 45 keys con-
sisting of the full alphabet and 0–9 numeric keys. The
first row of keys are labeled F1, F2, F3, F4 and F5.
These keys are always associated with a key function
shown on the screen. Reference the MAIN screen
shown below. The F1 key is associated with the VIEW
function, the F2 with the TR function, F3 with the MAN
function, F4 with the XO function and F5 with the
SETUP function. All the screens have functions that
correlate to the F keys as described here.
G R A C O
T O F +
P E N D A N T
T h u r
R e v
1 . 2 1
X
\
0 8 / 1 5 / 2 0 0 0
1 7 : 3 5 : 2 3
V I E W
T R
M A N
X O
S E T U P
F1
F2
F3
F4
F5
Reference the screen map on page 28.
The first line of the MAIN menu shows that this is the
GRACO TOF+ PENDANT. TOF+ is an acronym for
Therm-O-Flow Plus. The screen shows the current
day is Thursday. The rev. of the software is 1.21 and
the current time and date are also shown. (The date is
MM/DD/YEAR, the time is a 24 hr clock HH:MM:SS,
17:35:23 represents 5:35:23 pm.
The
VIEW screens are accessed by pressing F1
(VIEW). These screens are for:
Viewing and sending of recipes
Viewing 7 day timer settings
Viewing pump crossover zone settings.
The F2
TR selection accesses the TIMER screens. In
these screens the 7 Day Timer can be turned on and
off.
The F3
MAN selection accesses the MANUAL opera-
tion screen. Here any SV can be can be sent to any
zone controller, as well as placing the controls in RUN
or STOP mode.
The F4
XO selection is for turning off and on the
X-Over control functions for those systems equipped
with the proper X-Over controllers. This screen is
never accessible for systems that are not dual ram
cross-over systems.
The F5
SETUP selection is for accessing all the
screens related to changing and editing the pendant
parameters. The SETUP screens are password
protected and are intended to be accessed only by
approved personnel, typically at system startup or
when heat zone components are being added to the
system.
When the 7 Day Timer is turned on, the clock icon
is turned on and shown on the MAIN screen. The
X-Over
X
icon is turned on when the cross-over
function is active.
The following functions are available in the SETUP
screens.
Change Password (the Graco default from the
factory is 11111111)
Change the number of CONFIGURED zones on
the system.
Edit the SV temperatures of the SETBACK, REC-
IPE #1 and RECIPE #2 recipes.
Setup the ZONE PID TYPES, ZONE NAMES,
ZONE ACTIVE/UNUSED STATUS
Edit the real time clock DATE/TIME.
Edit the 7 DAY TIMER Start/Stop times, for each
day of 4 different work weeks.
Configure the required settings for dual ram cross-
over (X-OVER) systems.
Load Graco default parameters to each tempera-
ture controller of the hot melt system.
Содержание Therm-O-Flow Plus
Страница 22: ...22 309085 Notes...
Страница 28: ...28 309085 Advanced Pendant Control Screen Map TI0683 See Next Page...
Страница 30: ...30 309085 Notes...
Страница 43: ...43 309085 Notes...
Страница 60: ...60 309085 Service For 400 480 and 575 VAC Supply Units Junction Box Schematic Fig 18 TI0673...
Страница 61: ...61 309085 Service For 240 VAC Supply Units Junction Box Schematic Fig 19 TI0673...
Страница 65: ...65 309085 Notes...