16
309085
Installation
Heater Resistance Checks
WARNING
ELECTROCUTION HAZARD
To reduce risk of injury or damage to
equipment, conduct these electrical
checks with the main disconnect OFF.
To check heater resistance:
1. Make sure the power is off and that the disconnect
switch is in the OFF position.
2. Make electrical resistance checks for the compo-
nents. Refer to
Control Panel Component
Layout on page 74 for wiring diagram information.
3. Replace any parts whose resistance readings do
not comply with the ranges listed in Table 1.
NOTE: Check resistance at ambient room tempera-
ture (63
– 77
F).
Table 1. Heaters
Zone Component
Between
Terminals
For Unit
Voltage
Platen Model
Code
Resistance Values
(ohms)
1
Ram Plate
3L1 & 3L2
240
B–1 or B–3
6.4 ohms + .65 ohms
Heaters from
J–Box or
B–2
5.5 ohms + .55 ohms
J–Box or
Control Box
Not 240
B–1 or B–3
25.5 ohms + 2.6 ohms
B–2
22 ohms + 2.2 ohms
3L2& 3L3
240
B–1 or B–3
6.4 ohms + .65 ohms
B–2
5.5 ohms + .55 ohms
Not 240
B–1 or B–3
25.5 ohms + 2.6 ohms
B–2
22 ohms + 2.2 ohms
3L3 & 3L1
240
B–1 or B–3
6.4 ohms + .65 ohms
B–2
5.5 ohms + .55 ohms
Not 240
B–1 or B–3
25.5 ohms + 2.6 ohms
B–2
22 ohms + 2.2 ohms
Any leg to
ground
Any
Any
At least 70K ohms
2
Pump
Heaters from
T1 & TC
240
Any
38.4 ohms + 3.8 ohms
J–Box with
jumpers
installed
B1 & BC
240
Any
38.4 ohms + 3.8 ohms
installed
5L1 & 4L2
240
Any
38.4 ohms + 3.8 ohms
T1 & T2
Not 240
Any
153.6 ohms + 3.8 ohms
B1 & B2
Not 240
Any
153.6 ohms + 15.3 ohms
51 & 42
Not 240
Any
153.6 ohms + 15.3 ohms
3 thru 8 Check hose tag or valve manual for valve
Содержание Therm-O-Flow Plus
Страница 22: ...22 309085 Notes...
Страница 28: ...28 309085 Advanced Pendant Control Screen Map TI0683 See Next Page...
Страница 30: ...30 309085 Notes...
Страница 43: ...43 309085 Notes...
Страница 60: ...60 309085 Service For 400 480 and 575 VAC Supply Units Junction Box Schematic Fig 18 TI0673...
Страница 61: ...61 309085 Service For 240 VAC Supply Units Junction Box Schematic Fig 19 TI0673...
Страница 65: ...65 309085 Notes...