Solution
ETE0
Record
Purge Not
Complete
The system was unable
to complete a purge
sequence.
An indication that the
system either could
not complete or was
interrupted before
completing a gun purge.
No action required.
Solvent flow switch not
working.
Replace switch.
Solvent flow is too low
to actuate the solvent
switch.
Increase solvent
pressure to drive a
high purge flow rate
Gun is not triggered.
Operator must continue
flushing for configured
time, until the booth
control indicates purge is
completed.
SPD1
Alarm
Gun Purge
Incomplete
The system timed out
without reaching the
user-specified volume of
solvent for a purge.
Mix manifold was not set
to flush position, blocking
solvent flow to the spray
gun.
Set manifold to flush
position.
3A6287E