Operation Using a Programmable Logic Controller (PLC)
Network
Network
Network
Output
Output
Output ID
ID
ID
Modbus
Modbus
Modbus
Register
Register
Register
Parameter
Parameter
Parameter Name
Name
Name
Data
Data
Data Type
Type
Type
Units
Units
Units
Range
Range
Range
0005
41010
Actual Mix Ratio
Component C
uint32
NONE
0 - 100000
0006
41012
Actual Mix Ratio
Component D
uint32
NONE
0 - 100000
0007
41014
Actual Mix Potlife
Remaining Stage 1
uint32
sec
0 – 59940
0008
41016
Actual Mix Potlife
Remaining Stage 2
uint32
sec
0 – 59940
0009
41018
Actual Mix Potlife
Remaining Stage 3
uint32
sec
0 – 59940
0010
41020
Gun Trigger Input
Status
uint32
NONE
0 := Gun not triggered
1 := Gun triggered
0011
41022
Active Gun
uint32
NONE
1 - 3
0012
41024
Job Number
uint32
NONE
0 - 9999
0013
41026
Job Total Sprayed
Volume
uint32
cc
0 - 999999999
0014
41028
Job Solvent Volume
uint32
cc
0 - 999999999
0015
41030
Safety Interlock Input
Status
uint32
NONE
0 := Open
1:= Closed
0016
41032
Active Recipe Number
uint32
NONE
0 - 40, 61
0017
41034
Active Recipe Material
A
uint32
NONE
0, 1 - 30, 61
0018
41036
Active Recipe Material
B
uint32
NONE
0, 31 - 38, 61
0019
41038
Active Recipe Material
C
uint32
NONE
0, 39 - 46, 61
0020
41040
Active Recipe Material
D
uint32
NONE
0, 47 - 54, 61
0021
41042
Active Recipe Ratio
Set Point Component
A
uint32
NONE
0 - 100000
0022
41044
Active Recipe Ratio
Set Point Component
B
uint32
NONE
0 - 100000
0023
41046
Active Recipe Ratio
Set Point Component
C
uint32
NONE
0 - 100000
0024
41048
Active Recipe Ratio
Set Point Component
D
uint32
NONE
0 - 100000
0 = Off
1 = Standby
2 = Busy
3 = Flushing
0025
41050
Pump 1 Status
uint32
NONE
4 = Priming
32
3A6287E