Diagnostic
Diagnostic
Diagnostic Screens
Screens
Screens
Diagnostic
Diagnostic
Diagnostic Screen
Screen
Screen 1
1
1
Figure 87 Diagnostic Screen 1
Use this screen to test and verify proper wiring for
all inputs to the EFCM. (See installation manual for
details.) The screen shows all available inputs to the
EFCM, but only highlights those that are relevant
to the system configuration. All inputs are normally
open. When the input sees a switch closure the
status indicator on the screen will turn green.
Diagnostic
Diagnostic
Diagnostic Screen
Screen
Screen 2
2
2
Figure 88 Diagnostic Screen 2
This screen can be used to determine whether any of
the EFCM outputs are currently on or off. The screen
shows all available outputs from the EFCM, but
only highlights those that are relevant to the system
configuration. The status indicator next to each
output indicates the output is ON when it is green.
Diagnostic
Diagnostic
Diagnostic Screens
Screens
Screens 3–10
3–10
3–10
Figure 89 Diagnostic Screen 3–10
Diagnostic screens 3–10 are only available for color
change modules that are currently connected to the
PD3K+ system. These screens provide real time
status of the color change valve outputs by changing
the status indicator from white to green when the
system energizes that solenoid. The user may scroll
through the boards with the up and down arrows, or
jump directly to a specific color change module by
selecting it from the drop-down box.
3A6287E
93