To
To
To Clear
Clear
Clear Error
Error
Error and
and
and Restart
Restart
Restart
NOTE:
NOTE:
NOTE: When a deviation or alarm occurs, be
sure to determine the error code before resetting
it. If you forget which code occurred, go to the
, to view the last 200 errors,
with date and time stamps.
If an alarm has occurred, correct the cause before
resuming operation.
To acknowledge a deviation or clear an alarm, press
on the Advanced Display Module. Users also
may acknowledge and clear errors via a network
device.
INPUT REGISTER 08: Clear Active Alarm
in
ProMix PD3K+ Network Inputs, page 34
Gun
Gun
Gun Trigger
Trigger
Trigger Input
Input
Input Function
Function
Function
The Gun Trigger Input signals the controller when
the gun is triggered. The gun icon on the Advanced
Display Module shows spray when the Gun Trigger
Input is activated.
If a pump fails, pure resin or catalyst could spray
indefinitely if the unit does not detect the condition
and intervene, which is why the Gun Trigger Input
is so important.
If the unit detects through the Gun Trigger Input
signal that the gun is triggered, yet one or both of the
pumps are not running, a Flow Not Detected Alarm
(F8D1) occurs after 10 seconds (default) and the
system goes into Standby.