CALIBRATE Screen continued
NOTE: The WATLOW Temperature Controllers located on the front panel of the machine are as indicators
only, no adjustment of these controllers are required.
TEMP SET PT N7:54 button/indicator
(Mixed Material Temperature Set Point Control)
This button/indicator shows the range of the mixed material temperature (this range is shown in
±
C
°
). For example:
If the mixed material temperature was set to 90C
°
and TEMP SET PT N7:54 indicator was set to “10” the
temperature of the material would be between 80C
°
and 100C
°
.
To change the TEMP SET PT N7:54 indicator
(Mixed Material Temperature Set Point)
do the following:
1.
Select TEMP SET PT N7:54 button, a numeric keypad should appear.
2.
Enter in the new material temperature range required.
3.
Press the ENTER button.
4.
The new material temperature range should appear in the TEMP SET PT N7:54 indicator.
PSI HIGH SET PT N7:40 button/indicator
(Pump Servo PSI High Set Point)
This button/indicator shows the material pressure at which the machine pump servomotor will stop generating
material pressure (shut off) in psi or MPa.
To change the PSI HIGH SET PT N7:40 indicator
(Pump Servo PSI High Set Point)
do the following:
1.
Select PSI HIGH SET PT N7:40 button, a numeric keypad should appear.
2.
Enter in the new material high shut off pressure required.
3.
Press the ENTER button.
4.
The new material high shut off pressure should appear in the PSI HIGH SET PT N7:40 indicator.
PSI LOW SET PT N7:42 button/indicator
(Pump Servo PSI Low Set Point)
This button/indicator shows the material pressure at which the machine pump servomotor will start generating
material pressure (start up) in psi or MPa.
To change the PSI LOW SET PT N7:42 indicator
(Pump Servo PSI Low Set Point)
do the following:
1.
Select PSI LOW SET PT N7:42, a button at numeric keypad should appear.
2.
Enter in the new material low start up pressure required.
3.
Press the ENTER button.
4.
The new material high shut off pressure should appear in the PSI LOW SET PT N7:42 indicator.
RESET TO FACTORY button