7
CALIBRATE Screen
NOTE: The WATLOW Temperature Controllers located on the front panel of the machine are as indicators
only, no adjustment of these controllers are required.
T/C WIND SET PT N7:60 button/indicator
(Temperature Control Window Set Point)
This button/indicator shows the range of the material temperature (this range is shown in
±
C
°
). For example: If the
material temperature was set to 90C
°
and the T/C WIND SET PT indicator was set to “10” the temperature of the
material would be between 80C
°
and 100C
°
.
To change the T/C WIND SET PT N7:60 indicator
(Temperature Window Control Set Point)
do the following:
1.
Select T/C WIND SET PT N7:60 button, a numeric keypad should appear.
2.
Enter in the new material temperature range required.
3.
Press the ENTER button.
4.
The new material temperature range should appear in the T/C WIND SET PT N7:60 indicator.
T/C SHUT PT N7:51 button/indicator
(Temperature Control Shutdown Set Point)
This button/indicator shows the absolute maximum material temperature in C
°
. For example: If this indicator was
set to 110C
°
and the material exceeded this temperature (such as a catastrophic heater failure), the power to all the
heater ovens will be disabled.
To change the T/C SHUT PT N7:51 indicator
(Temperature Control Shutdown Set Point)
do the following:
1.
Select T/C SHUT PT N7:51 button, a numeric keypad should appear.
2.
Enter in the new maximum material temperature required.
3.
Press the ENTER button.
4.
The new material maximum temperature should appear in the T/C SHUT PT N7:51 indicator.