12
PUMP PRESSURE screen continued
SYSTEM HIGH PRESSURE ALARM indicator
This indicator is illuminated when the material outlet hose and / or material mold pressure is at a high
pressure shutdown condition, previously set with the PSI HIGH SET PT N7:40 button seen in the
CALIBRATION screen section. This indicator usually becomes active when there is a catastrophic loss of
pressure. When indicator is activated, the material pump servomotor is stopped.
For more information on
the LOW PRESSURE SHUTDOWN SETPOINT settings, see the CALIBRATION screen section of this
manual.
SYSTEM LOW PRESSURE ALARM indicator
This indicator is illuminated when the material outlet hose and / or material mold pressure is at a low
pressure shutdown condition, previously set with the PSI LOW SET PT N7:42 button seen in the
CALIBRATION screen section. This indicator usually becomes active when there is a high pressure
condition. When indicator is activated, the material pump servomotor is stopped.
For more information on
the HIGH PRESSURE SHUTDOWN SETPOINT settings, see the CALIBRATION screen section of this
manual.
Optional A Vacuum Pump (B Vacuum Pump) button
These buttons control the “A” and “B” material tank vacuum pump.
ON button
When selected the vacuum pump is currently activated.
OFF button
When selected the vacuum pump is currently deactivated.
Optional A TANK AGITATOR and B TANK AGITATOR buttons
The Agitator Speed Controller enables/disables the electric agitator and also increases/decreases the tank
agitator speed.
OFF button
The tank agitator is disabled and the material in the tank is not agitated.
ON button
The tank agitator is enabled and the material in the tank is being agitated to low or high speed.
LOW SPEED button
The tank is agitated at the minimum speed when the ON button is selected.
HIGH SPEED button