English
Clamp Multimeter METRACLIP 86
- Above 1000V, a repetitive beep indicates that the voltage being
measured is greater than the safety voltage for which the device is
guaranteed. The display indicates "OL"
4.2.2
AC voltage measurement
Measurement
range
0.15 V to
59.99 V
60.0 V to
599.9 V
600 V to 1000V RMS
1400V peak (1)
Specified
measurement
range (2)
0 to 100% of the measurement range
Uncertainties
from 0.15V to 5.99V
± (1% R + 10 pt)
from 6.00V to
59.99V
± (1% R +3 pt)
± (1% R +3 pt)
Resolution
0.01V
0.1V
1V
Input impedance
10M
Ω
Note (1) - The display indicates "OL" above 1000V (1400V in PEAK mode).
- Above 1000V, a repetitive beep indicates that the voltage being
measured is greater than the safety voltage for which the device is
guaranteed. The display indicates "OL".
- Bandwidth in AC = 3 kHz
Note (2) Any value between zero and the min. threshold of the measurement range
(0.15V) is forced to "----" on the display.
35