Clamp Multimeter METRACLIP 86
English
4.2.14 Measurement of apparent AC power
Measurement
range (2) (4)
5 VA to
5999 VA
6.00 kVA to
59.99 kVA
60.0 kVA to
599.9 kVA
600 kVA (1)
Specified
measurement
range
1 to 100% of the
measurement
range
0 to 100% of the measurement range
Uncertainties
(3)
± (2% R +10 pt)
± (2% R +3 pt)
Resolution
1VA
10VA
100VA
1000VA
Note (1) - Display of O.L
- Above 600 kVA in single-phase (1000 V x 600 A).
- Bandwidth in AC in voltage = 3 kHz, in current = 3 kHz
Notes (2), (3) and (4) of the previous § apply.
4.2.15 Measurement of apparent AC+DC power
Measurement
range (2) (4)
5 VA to
5999 VA
6.00 kVA to
59.99 kVA
60.0 kVA to
599.9 kVA
600 kVA to
900 kVA (1)
Specified
measurement
range
1 to 100% of the
measurement range
0 to 100% of the measurement range
Uncertainties
(3)
± (2% R +10 pt)
± (2% R +3 pt)
Resolution
1VA
10VA
100VA
1000VA
Note (1) - Display of O.L
- Above 900 kVA in single-phase (1000 V x 900 A).
- Bandwidth in AC in voltage = 3 kHz, in current = 3 kHz
Notes (2), (3) and (4) of the previous § apply.
42