Clamp Multimeter METRACLIP 86
English
4.2.3
AC+DC voltage measurement
Measurement range (2)
0.15 V to
59.99 V
60.0 V to
599.9 V
600 V to 1000V
RMS (1)
1400V peak
Specified measurement
range
0 to 100% of the measurement range
Uncertainties
from 0.15V to 5.99V
± (1% R+10 pt)
from 6V to 59.99V
± (1% R +3 pt)
± (1% R +3 pt)
Resolution
0.01V
0.1V
1V
Input impedance
10M
Ω
Note (1) - The display indicates "OL" above 1000V (1400V in PEAK mode).
- Above 1000V (DC or RMS), a repetitive beep indicates that the voltage
being measured is greater than the safety voltage for which the device is
guaranteed.
- Bandwidth in AC = 3 kHz
Note (2) - Any value between zero and the min. threshold of the measurement
range (0.15V) is forced to "----" on the display.
Specific characteristics in MAX/MIN mode
in voltage (from 10Hz to 1kHz in AC
and AC+DC, and from 0.30V):
•
Uncertainties: add 1% R to the values in the tables above.
•
Capture time of the extrema: approximately 100ms.
Specific characteristics in PEAK mode
in voltage (from 10Hz to 400 Hz in AC
and AC+DC):
•
Uncertainties: add 1.5% R to the values in the tables above.
•
PEAK capture time: 1ms min. to 1.5ms max.
4.2.4
DC current measurement
Measurement
range (2)
0.00 A to
59.99 A
60.0 A to
599.9 A
600 A to 900 A (1)
Specified
measurement
range
0 to 100% of the measurement range
Uncertainties (2)
(zero corrected)
± (1% R+10
pt)
± (1% R +3 pt)
Resolution
0.01A
0.1A
1A
36