1. General description 

 
The CCM 1010 contact closure multiplexer system 
can  transmit  eight  independent  contact  closure 
signals unidirectionally over either one optical fiber 
or a serial data link (RS-232). A CCM 1010 TX/RX 
combination uses an optical wavelength of 850 nm 
over multimode fiber. 
 
Front panel LEDs indicate DC power good, correct 
transmission 

framing 

and 

correct 

receiver 

synchronisation. 
 
CCM  1010  equipment  comes  in  the  form  of  rack-
mountable  7TE  modules  to  be  slotted  into  a  TKH 
Security MC 11 or similar power supply cabinet, or 
as  stand-alone  units  (option  /SA)  needing  separate 
power supplies PSA 12 DC.  
 
 

2. Indications and connectors 

 
The CCM's front panel indications and connectors 
are listed in table 1 below. 
 

CCM TX 

 

o

 

   (optical connector)

 

optical out 

o

 

 

8xCC (37-pin conn.)

 

CC inputs, data out 

Indicator LEDs 

 

 

*DC 

DC power good 

 

*FR 

signal framing OK 

CCM RX 

 

o

 

 

(optical connector)

 

optical in 

o

 

  8xCC (37-pin conn.)

 

CC outputs, data in 

Indicator LEDs 

 

 

*DC 

DC power good 

 

*SYNC 

input signal sync OK 

Table 1. CCM front panel features 

 
 

3. Installation instructions 

 

3.1 General 

 
- Insert  the  units  into  an  appropriate  MC  11  or 
similar power supply cabinet (and/or connect stand-
alone  units  to  their  power  supplies)  and  connect 
appropriate  cabling.  Pin  assignments  are  listed  in 
section 5. 
 

- After  switching  on  the  system,  check  whether  all 
LEDs glow green. If the FR LED on the CCM TX 
is red, that unit is faulty. If the SYNC  LED on the 
RX  lights  red  while  the  FR  LED  glows  green, 
check the optical link first. 
 
 

3.2 Link type 

 
The unit tries to establish and use a link type based 
on  link  input  measurements  (default  autodetect 
mode; it holds on to an interface as long as signal is 
present). To permanently select either the optical or 
the RS-232 link, internal dip switches can be set. 
To  access  these  switches,  take  out  the  front  panel 
Phillips head screws indicated in figure 1 and slide 
out  the  front  panel/circuit  board  assembly.  Dip 
switches S1/S2 select between autodetect, the serial 
link and the optical link (see figure 2 and table 2). 

 

 

Figure 1. Front panel features of the CCM 

1010 TX (left) and RX 

CCM 1010 

 

Unidirectional optical and digital contact closure multiplexer system 

 

USER MANUAL 

 

CCM TX

DC

FR

8xCC

37/19

20/1

CCM RX

DC

SYNC

37/19

20/1

8xCC