background image

 

User’s Guide 

 

 
 
MultiMaster™ Digital MultiMeter Series 
With PC Interface 
 
Models: 
 MM560 
 MM570 
 

Содержание MultiMaster MM560

Страница 1: ...User s Guide MultiMaster Digital MultiMeter Series With PC Interface Models MM560 MM570...

Страница 2: ...prevent damage in transit This warranty does not apply to defects resulting from action of the user such as misuse improper wiring operation outside of specification improper maintenance or repair or...

Страница 3: ...fer to the explanation in this Manual Caution Risk of electric shock Earth Ground Double Insulation or Reinforced insulation Fuse AC Alternating Current or Voltage DC Direct Current or Voltage AC DC C...

Страница 4: ...that the terminals are not live 12 If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired 13 The product is intended only for...

Страница 5: ...DC CURRENT Range Accuracy Burden Voltage 500 00 A 0 15 20d 0 15mV A 5000 0 A 0 1 20d 0 15mV A 50 000mA 0 15 10d 3 3mV mA 500 00mA 0 1 20d 3 3mV mA 5 0000A 0 5 10d 0 03V A 10 000A 0 5 20d 0 03V A 10A c...

Страница 6: ...o 20kHz 1kHz to 20kHz 500 00mV 0 5 20d 1dB 5 0000V 50 000V 0 8 20d 2dB 500 00V 0 5 20d 3dB 1000 0V Unspecified Unspecified 20kHz to 100kHz 500 00mV 2 0 40d 5 0000V 50 000V 4 0 40d 500 00V 1000 0V Unsp...

Страница 7: ...000mA 500 00mA 3 3mV mA 5 0000A 10 000A 0 7 50d 1 0 40d 0 03V A 1kHz to 10kHz 500 00 A 5000 0 A 0 15mV A 50 000mA 500 00mA 2 0 50d 3 3mV mA 5 0000A 10 000A Unspecified Unspecified 0 03V A 10A continuo...

Страница 8: ...range 10V min 500V range 100V min Sensitivity 1000V range 900V min FREQUENCY LOGIC LEVEL Range 5 0000Hz to 2 00000MHz Accuracy 0 002 4d Sensitivity 2 5Vp square wave DUTY CYCLE Range 0 10 to 99 99 Acc...

Страница 9: ...equency bandwidth for non sinusoidal waveforms Sensing DC AC True RMS AC DC True RMS Digital Display 4 4 5 digits 50000 count 5 4 5 digits 500000 count for DCV 6 digits 999999 count for Hz Bar Graph D...

Страница 10: ...for DMMs was first released in IEC61010 1 2nd Edition in year 2001 and was yet an UL published standard at the time this manual was written E M C Meets EN61326 1997 1998 A1 EN61000 4 2 1995 and EN6100...

Страница 11: ...he average value is then scaled upward calibrated to read the RMS value of a sine wave In measuring pure sinusoidal waveform this technique is fast accurate and cost effective In measuring non sinusoi...

Страница 12: ...the AC bandwidth of the DMM Therefore wide AC bandwidth plays an important role in a high performance DMM In reality complex waveforms noise and distorted waveforms contain a much higher frequency spe...

Страница 13: ...multimeters are Autoranging with manual override Smart Power Auto Power Off APO Smart Power automatically shuts the meter down after approximately 17 minutes of inactivity APO can be disabled on powe...

Страница 14: ...T key to toggle between AC and dBm 4 In VDC press the SELECT key to toggle between DC and AC DC 5 In mV press the SELECT key to toggle between DC AC and AC DC 6 Read the voltage measurement on the dis...

Страница 15: ...an the phase to earth voltage To avoid accidentally exceeding the voltage rating of the protection fuse s always consider the phase to phase voltage as the working voltage for the protection fuse s 4...

Страница 16: ...15 6 For Continuity tests if the resistance is less than the threshold 20 to 200 an audible tone will sound...

Страница 17: ...nge to automatically get the most appropriate trigger level When activated from voltage function you can also press the RANGE key momentarily to select another trigger level range manually The analog...

Страница 18: ...only 1 Insert the T1 Temperature Probe into the COM and TEMP input jacks observing polarity 2 Insert the T2 Temperature Probe into the 10A and mA A input jacks observing polarity 3 Set the function s...

Страница 19: ...be disabled automatically in this mode Smart Power Auto Power Off Smart Power shuts the meter down automatically after approximately 17 minutes of inactivity The 17 minute time period is reset any tim...

Страница 20: ...the meter from any circuit remove the test leads from the input jacks and turn OFF the meter before opening the case Do not operate with open case Install only the same type of fuse or equivalent Cle...

Страница 21: ...M6 IEC6LF22 FS1 for A mA current input For MM560 0 63A 500V F IR 200kA fast acting fuse For MM570 1A 1000V F IR 10kA acceptable alternative 0 44A 1000V IR 10kA FS2 for A current input For MM560 12 5A...

Отзывы: