Chapter 12 - Optional Accessories -
201
G8 Super Cruiser Operator’s Manual MY19 - REV 0
7. Replace the dust cap on the filler connector.
8. There is a filter within the filler connector in the
reservoir. If pumping is very difficult, the filter
could be blocked. In this case, dismantle and clean
the filter.
Groeneveld Auto Greaser - Maintenance & Testing
1
2
Testing Electronic Timer
STEP SWITCH TEST
This checks the step switch contacts in all positions.
1. Set the step switch to position ‘test A’.
2. Activate the electronic timer by switching on the
ignition.
3. Press the ‘test’ button.
4. Wait for the audible alarm signal then release the
‘test’ button.
5. Within 5 seconds turn the step switch to the
required interval time position. Each position
produces a number of signals: position 1 gives one
signal, position 2 two signals etc.
6. The switch can be set to all positions. Positions
‘test A’ and ‘test B’ will not produce an alarm
signal.
7. End the test by switching off the ignition.
ACCELERATED CYCLE TEST
This allows you to test a timing cycle without waiting
the full set time interval. It sets the time interval at
1/20th of its duration.
1. Set the step switch to position ‘test A’.
2. Press and hold the ‘test’ button.
3. Switch the ignition on while still keeping the ‘test’
button pressed in.
4. The alarm signal buzzer will now sound. The ‘test’
button must be pressed as long as the alarm
signal continues.
5. Within 5 seconds of the end of the alarm signal
turn the step switch to the required position.
6. The electronic timer is now fully operational; the
time intervals are now 1/20th of their usual times.
7. End the test by switching off the power supply.
NORMAL SYSTEM TEST
1. Switch the ignition on.
2. Press the ‘test’ button; a normal lubrication cycle
will then follow. The switch can be set in any
position except ‘test A’ or ‘test B’.
After this test the electronic timer will work at the
interval set.
The ‘test B’ position is only for use with the test or
read-out unit.
Right:
Filling the
pump unit.
Содержание Super Cruiser G8
Страница 1: ...Super Cruiser G8 Operator s Manual MY19 GA8700989 REV 0 APR 2019 FROM SERIAL 202114 ...
Страница 12: ...8 Chapter 2 Safety G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Страница 18: ...14 Chapter 3 General Information Specs G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Страница 34: ...30 Chapter 4 Cabin G8 Super Cruiser Operator s Manual MY19 REV 0 Power Distribution Box Fuse Box Layouts ...
Страница 43: ...Chapter 4 Cabin 39 G8 Super Cruiser Operator s Manual MY19 REV 0 CANtrak System Parameters Monitored ...
Страница 58: ...54 Chapter 4 Cabin G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Страница 74: ...70 Chapter 7 Pre Operation G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Страница 104: ...100 Chapter 8 Operation G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Страница 210: ...www goldacres com au ...