Chapter 12 - Optional Accessories -
175
G8 Super Cruiser Operator’s Manual MY19 - REV 0
Flow Meter - FM-1100
• Maximum Total: 9999
• Auto Shut Off: 3 minute
• Auto Wake Up: With Flow
Operation
CAUTION: Exposure to chemical can cause serious
injuries, always wear proper protective clothing and
devices when transferring chemical. Refer to and
follow chemical manufacturers instructions.
The FM-1100 flow meter will start working
automatically when flow is detected.
The LCD display will show the following:
- LOW - Low battery indicator
- CUR - Current Total indicator
- CUM - Cumulative total indicator
- GAL - Gallons indicator
- LTR - Litre indicator
- CNT - counts indicator
- CAL - Calibration indicator
The meter displays and stores:
• A resettable CURRENT TOTAL (CUR)
• A non-resettable CUMULATIVE TOTAL (CUM)
• A COUNTS calibration value (CNT)
911-729 (4/12, Rev. C)
7
Meter Operation
The meter displays and stores:
• A resettable CURRENT TOTAL (CUR)
• A non-resettable CUMULATIVE TOTAL (CUM)
• A COUNTS calibration value (CNT)
The MODE button performs the following functions:
1. If the display is off, press MODE button to display
current total (CUR).
2. Use MODE button to cycle between CURRENT
TOTAL (CUR) and CUMULATIVE TOTAL (CUM).
NOTE:
After approximately 30 seconds, display will auto-
matically switch from CUMULATIVE TOTAL (CUM) back
to CURRENT TOTAL (CUR).
3. Press and hold MODE button for 3–5 seconds to
show Volume Unit Selection. Press INCREASE or
DECREASE buttons to cycle through volume units.
When desired units are flashing, press MODE button
to save selection and return to CURRENT TOTAL
(CUR).
Volume Unit Selection choices are: GALLONS (GAL),
LITERS (LTR), or COUNTS (CNT).
NOTE
: To reset CURRENT TOTAL (CUR) to Zero, press
and hold DECREASE button for 2 seconds or more while
CURRENT TOTAL (CUR) is displayed.
NOTE:
Meter will not enter Volume Unit Selection mode
if pump is running.
CUMULATIVE TOTAL CANNOT BE RESET - EVEN BY
REMOVING THE BATTERY.
• The flow meter display will turn on whenever flow is
detected.
• The flow meter will turn off and blank the display after
a 3-minute period of button or flow inactivity. Any
unsaved changes will not be saved.
Calibration Procedures
• Calibration procedures are the same for both the 90°
and inline meters.
• To ensure accuracy, purge all air from pump/meter
system before calibrating.
To CALIBRATE (CAL) meter
:
1. Press MODE button to turn meter on.
2. Press and hold MODE button for 3–5 seconds to
show Volume Unit Selection. Press INCREASE or
DECREASE buttons to select desired Volume Units.
3. Press and hold MODE button again for 3–5 seconds
to enter Calibration Mode (CAL).
4. CAL and chosen Volume Unit (GAL or LTR) will blink
together. Numeric Display will show default values as
listed below.
NOTE:
To use a calibrated container with a volume other
than the default values, press INCREASE or DECREASE
buttons to change value shown on Numeric Display.
5. To complete CALIBRATION for GALLONS (GAL) or
LITERS (LTR), pump the exact amount shown on
Numeric Display.
6. Press MODE button for 3–5 seconds to SAVE the
CALIBRATION. Display will show CAL if CALIBRA-
TION was successful.
NOTE:
If MODE button is pressed for less than 3 sec-
onds, CALIBRATION will be aborted and display will
show Err (Error) to indicate the CALIBRATION was not
successful. Display will return to CURRENT TOTAL
(CUR) without making any changes.
To CALIBRATE (CAL) meter using COUNTS (CNT) value:
NOTE:
No pumping is required to complete CALIBRA-
TION (CAL) for COUNTS (CNT).
1. Press MODE button to turn meter on.
2. Press and hold MODE button for 3–5 seconds to
show Volume Unit Selection. Press INCREASE or
DECREASE buttons to select COUNTS (CNT).
3. Press and hold MODE button again for 3–5 seconds
to enter Calibration Mode (CAL).
D
MODE/
ON
INCREASE
DECREASE/
ZERO
The FM-1100 Series Flow Meter has three push buttons:
1
MODE or
2
INCREASE
3
DECREASE
“ON” button
(up arrow) button
(down arrow) or
“ZERO” button
The FM-1100 Flow Meter is a positive displacement
fluid metering unit.
• Accuracy: +-0.5%
• Flow Range: 9-136 L/min
• Maximum Pressure: 410 kPa (60 PSI)
Continued over page
Содержание Super Cruiser G8
Страница 1: ...Super Cruiser G8 Operator s Manual MY19 GA8700989 REV 0 APR 2019 FROM SERIAL 202114 ...
Страница 12: ...8 Chapter 2 Safety G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Страница 18: ...14 Chapter 3 General Information Specs G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Страница 34: ...30 Chapter 4 Cabin G8 Super Cruiser Operator s Manual MY19 REV 0 Power Distribution Box Fuse Box Layouts ...
Страница 43: ...Chapter 4 Cabin 39 G8 Super Cruiser Operator s Manual MY19 REV 0 CANtrak System Parameters Monitored ...
Страница 58: ...54 Chapter 4 Cabin G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Страница 74: ...70 Chapter 7 Pre Operation G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Страница 104: ...100 Chapter 8 Operation G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Страница 210: ...www goldacres com au ...