Chapter 8 - Operation -
97
G8 Super Cruiser Operator’s Manual MY19 - REV 0
Flushing
The following information is provided as a general
guide for flushing your sprayer following a spray
application.
For more specific information regarding flushing, and
decontamination, specific to the products that you
are applying, it is recommended that you consult the
chemical label or your chemical supplier.
TO USE THE FLUSH WATER TANK TO FLUSH
PUMP & BOOM NOZZLES ONLY
This procedure will allow rinse water back into the
main spray tank and through the boom recirculation
system.
1. Turn spray pump off
2. Press the switch to ‘Suction rinse tank’ rather than
the main product tank. A buzzer will sound in
the cabin and at the EZ Control station,until it is
switched back to main tank.
3. Set Raven console into manual mode. Ensure that
Boom Recirculation is turned ‘OFF’.
4. Switch all boom sections to ON
5. Hold increase button for 15-20 secs. This will
ensure that fast close valve is fully open to direct
all flow to booms (This will eliminate bypass from
the booms to main tank).
6. Turn spray pump ON. The pump will now draw
water from the flush water tank and direct all
flow to the booms.
7. Keep boom switches on until the contents of the
flush water tank has been run through the booms.
NOTE:
If the pressure gauge increases dramatically,
hold decrease to reduce.
TO FLUSH ENTIRE SYSTEM - PUMP, BOOM &
TANK
1. Drain the main tank.
2. Connect to external water source to provide fresh
water supply.
3. Turn main tank fill tap OFF to direct external water
supply to the fill manifold under pressure.
4. Engage tank rinse nozzles with the ball valve on EZ
control and allow rinsate to drain out through the
main tank drain.
5. Add a quantity of fresh water (a minimum of
approximately twice the pumps capacity) to the
rinse water tank as per filling instructions.
6. Turn on pump with agitator and bypass open to
allow fresh water to circulate.
7. Turn off all taps to allow the pressure relief valve
to blow off and purge the ‘relief to tank’ line.
8. Operate induction equipment (if fitted), with a
quantity of fresh water in order to flush venturi
system. Lower the induction hopper and open
drain valve while the agitation jet is running.
9. Now follow the instructions for boom flushing -
keep ball valve drawing from rinse water tank.
10. Turn on boom recirculation switch.
NOTE:
The boom sections can be pulsed ON/OFF
to flush/rinse the tips and nozzle bodies.
11. Turn off boom recirculation switch.
12. Stop spray pump and close all valves
13. Return pump suction to ‘Suction Main Tank’.
Содержание Super Cruiser G8
Страница 1: ...Super Cruiser G8 Operator s Manual MY19 GA8700989 REV 0 APR 2019 FROM SERIAL 202114 ...
Страница 12: ...8 Chapter 2 Safety G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Страница 18: ...14 Chapter 3 General Information Specs G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Страница 34: ...30 Chapter 4 Cabin G8 Super Cruiser Operator s Manual MY19 REV 0 Power Distribution Box Fuse Box Layouts ...
Страница 43: ...Chapter 4 Cabin 39 G8 Super Cruiser Operator s Manual MY19 REV 0 CANtrak System Parameters Monitored ...
Страница 58: ...54 Chapter 4 Cabin G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Страница 74: ...70 Chapter 7 Pre Operation G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Страница 104: ...100 Chapter 8 Operation G8 Super Cruiser Operator s Manual MY19 REV 0 ...
Страница 210: ...www goldacres com au ...