Страница 1: ...Fusion Par FP7 User Manual Software version 1 0 0 4 ...

Страница 2: ...ated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Manufacturer s head office German Light Products GmbH GLP Industriestrasse 2 76307 Karlsbad Germany Tel Germany 49 7248 92719 0 Service Support EMEA GLP Industriestrasse 2...

Страница 3: ... FP7 overview 11 4 Features 12 Virtual color wheel 12 RGBW color mixing 12 Shutter effect 13 Color temperature 13 5 Preparation for use 14 Included Items 14 Installation 14 Connecting to power 16 Connecting to a DMX control data link 18 6 Control menus and onboard display 19 Control menus 19 7 IR Remote 25 8 Service 26 Cleaning 26 Optical accessories 26 9 Control menu layout 27 10 DMX control mode...

Страница 4: ...DMX Channel Index that is also available for download from www glp de The FP7 is intended for use by experienced professionals with the knowledge and skills to set up operate and maintain high powered remotely controlled lighting equipment safely and efficiently These operations require expertise that may not be provided in this manual Respect all warnings and directions given in this user manual ...

Страница 5: ... software release notes and download the correct version of this user manual on the GLP website if necessary Make this user manual available to all persons who will install operate or service the fixture Save this user manual for future reference If you have any questions about the safe operation of the fixture please contact an authorized GLP distributor see list of distributors at www glp de GLP...

Страница 6: ... manual matches the version installed in the product You can download the correct version of this user manual if necessary Make the user manual available to all installers and operators and save the manual for future reference If you have questions about the safe operation of the FP7 please contact an authorized GLP distributor see list of distributors at www glp de Use the product only as directe...

Страница 7: ...ct condition and rated for the electrical requirements of all connected devices Use minimum 14 AWG or 1 5 mm2 power input and relay cables that are minimum 16 A rated and temperature rated to suit the application In the USA and Canada the cables must be UL listed type SJT or equivalent In the EU the cables must be type H05VV F or equivalent Do not connect devices to power in a chain using their po...

Страница 8: ...Do not expose the front of the product to sunlight or any other intense light source even from an angle Eye safety The FP7 is classified as a Risk Group 2 product according to EN 62471 Possibly hazardous radiation emitted Do not stare into the light output from the product May be harmful to the eyes Do not look at the product s light output with optical instruments or any device that may concentra...

Страница 9: ...cifically designed and rated for the purpose Check that the hardware is in perfect condition Fasteners must be steel grade 8 8 strength or better Rigging clamps must be half coupler type that completely encircle the rigging truss chord If the product is installed in a location where it may cause injury or damage if it falls install as directed in this manual a safety cable or similar secondary att...

Страница 10: ...nt face of any fixture is shielded or points away from the sun even when not in use Avoid pointing other high powered beam lights directly at the fixture Do not pick up or carry the fixture by the front bezel The LCD display is also fragile Picking up or supporting the fixture in these spots could result in damage that is not covered by the product warranty Use only original spare parts Any struct...

Страница 11: ... E Spring loaded optical accessory retaining latch F Fold out foot G Safety cable attachment point H Control panel and display I DMX OUT THRU 5 pin XLR IP65 rated J AC mains power IN Neutrik powerCON TRUE1 TOP K AC mains power THRU Neutrik powerCON TRUE1 TOP L DMX IN 5 pin XLR M Quarter turn lock mounting points for 100 mm omega clamp Figure 2 Fusion Par FP7 overview I L G J K D F B A C M H E ...

Страница 12: ...nlight Using the Floorstand Mounting bracket that is supplied with the fixture the FP7 can be placed upright on a level surface fastened to a secure surface in any orientation or suspended from a suitable structure such as a rigging truss by means of an omega clamp and rigging clamp optional accessories A spring loaded latch on the front of the fixture allows quick and easy mounting of optical acc...

Страница 13: ... s electronic shutter effect provides ramp up and ramp down effects a variable speed strobe with strobe pause effects and instant blackout and full intensity Color temperature Color temperature can be varied continuously from 2700 K to 8000 K on a separate CT channel in DMX Mode 1 ...

Страница 14: ...d in water The FP7 can be used when placed on a level surface fastened to a surface in any orientation or fastened to a structure such as a rigging truss in any orientation Keep the fixture at least 0 5 m 20 in away from combustible materials including curtains and stage scenery when the fixture is installed Placing on a surface You can stand the impression FP7 upright on its Floorstand Mounting b...

Страница 15: ...er to center distance of 100 mm 3 94 ins for the quarter turn fasteners on an omega bracket It also has a hole that accepts an M10 bolt Before installing check that all mounting hardware and fasteners are approved for the weight that they will support and in perfect condition Fasteners must be high tensile steel To mount the fixture on a rigging truss either Bolt a rigging clamp to a suitable omeg...

Страница 16: ...ture to power at any other voltage or to an external dimmer The Fusion FP7 does not have a power ON OFF switch Power is applied to the fixture as soon as the power cord power cable that is connected to the fixture becomes live The FP7 has a 3 conductor IP65 rated Neutrik powerCON socket that accepts AC power from a Neutrik powerCON TRUE1 IP65 rated female cable connector To connect the fixture to ...

Страница 17: ...ed to the input cable Connect the power input cable to the MAINS IN socket see Figure 2 on page 11 following the instructions given in the previous section Connect a relay cable to the MAINS OUT socket see Figure 2 on page 11 of the first fixture and to the MAINS IN socket of the next fixture in the chain Continue until the chain is complete Do not expose cable connectors to bending forces by lett...

Страница 18: ...ecting to a DMX control data link The Fusion FP7 has 5 pin XLR DMX IN and DMX THRU sockets for connection to a USITT DMX512 data link Connectors use standard DMX pinout Pin 1 Ground Pin 2 ve data cold Pin 3 ve data hot Pins 4 and 5 are not used If using the fixture outdoors use only IP67 rated Neutrik 5 pin XLR connectors If you would like any advice with planning and installing a DMX link your GL...

Страница 19: ... the menu UP Scroll up or increase a number DOWN Scroll down or reduce a number ENTER Activate the control panel if it is in sleep mode Then enter a menu select a setting or implement a command After you have applied power to the fixture and the fixture has booted the panel displays the default screen with the fixture s DMX mode and DMX address DMX control is disabled when the control menus are ac...

Страница 20: ...ity of unexpected behavior from a powerful strobe light if the DMX signal fails we recommend that you set the fixture to Shut off when you are not running a stand alone program DMX Live DMX Live lets you view the current refresh rate of the DMX signal that the fixture is receiving It also lets you see the DMX values that the fixture is receiving for each individual effect Personal D Curve See Figu...

Страница 21: ... Lets you adjust the sensitivity of the audio trigger microphone Three sensitivity levels are available Normal the default setting High and Low To set up microphone sensitivity set Mic to On set Mic Sens to Normal and play music at a typical level If the fixture does not react at all or does not change lighting effects correctly in time with the music beat try increasing sensitivity to High If thi...

Страница 22: ... St Alone P Edit menu see later in this section when power is applied If the fixture begins to receive a DMX signal while running P1 P2 or P3 DMX commands will take priority by default If you want P1 P2 or P3 to take priority set Boot DMX Hi P to Off St Alone The St Alone menu gives a range of options for setting the fixture s autonomous stand alone behavior Test Runs a factory programmed sequence...

Страница 23: ...at as the step or scroll through and select different effects one by one starting with the color wheel and set a DMX value for each effect Once you have programmed the steps in your sequence use HoldTime to set the length of time that each step will be displayed before the fixture moves to the next step and use FadeTime to set the speed at which one step will crossfade into the next scene P Play L...

Страница 24: ... The Reset counter is resettable and can be returned to zero with the Clear command The Total counter is non resettable and will always show the number of hours the fixture has been powered on since it left the factory Temp Lets you view the current temperature for the LED board and the driver board Each board also has a resettable maximum temperature log that lets you view the maximum temperature...

Страница 25: ...r for commands from the IR remote is located in the center of the front surface of the fixture The IR remote is powered by a button cell battery If the remote seems to have stopped working the battery may be discharged Replace it with a new item The IR remote offers these functions Increase color intensity Toggle color on 100 off 0 Reduce color intensity Select a color preset Increase speed increa...

Страница 26: ...le and a softer beam A quick release locking system on the front of FP7 fixtures lets you install and remove the diffuser in seconds To install a diffuser on the front of the fixture See Figure 8 Pull the spring loaded locking pin A outwards away from the center of the fixture Insert one side of the diffuser behind the lip B in the front of the fixture opposite the locking pin then insert the othe...

Страница 27: ...al is received Play P2 Play P3 DMX Live Refresh XXX Hz Display current DMX signal refresh rate Color Red Green Blue White Shutter Dimmer CTO 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 Display DMX values being received for each effect Personal D Curve Linear Select dimming curve Theat Square Inv Sq D Speed Fast Dimmer optimized for speed Smooth Dimmer optimized for smoothness PWM 600 Hz Select...

Страница 28: ... over DMX signal Boot Select Auto At power on fixture returns to last action before power off DMX At power on fixture waits for DMX signal Static At power on fixture shows scene programmed in St Alone Static Program At power on fixture shows scene programmed in St Alone P Edit Prog 1 by default DMX Hi P On Off DMX High Priority if enabled a DMX signal takes priority over any action set for power o...

Страница 29: ...lue for each effect that you want to use in current scene Red 0 255 Green 0 255 Blue 0 255 White 0 255 Shutter 0 255 Dimmer 0 255 CTO 0 255 Reset No Yes Reset all effects values to zero HoldTime 000 999 Set time in seconds that scene is held FadeTime 000 999 Set time in seconds for scene to crossfade into next Prog 2 Same as Program 1 see above Prog 3 Same as Program 1 see above P Play Prog 1 No Y...

Страница 30: ... hours View total non resettable power on hours counter Clear Clear Cancel Clear resettable power on hours counter Temp LED Actual XXX C XXX F View current LED board temperature Max XXX C XXX F View resettable maximum LED temperature log Reset Max Clear Cancel Clear resettable maximum LED temperature log Driver Actual XXX C XXX F View current driver board temperature Max XXX C XXX F View resettabl...

Страница 31: ...perature control is available on a separate CTO channel Mode 1 Standard 1 Color wheel 2 Red 3 Green 4 Blue 5 White 6 Shutter 7 Master dimmer 8 CTO DMX Mode 2 6 Channel 6 Channel Mode provides a Master dimmer and RGBW color mixing A separate Shutter channel provides strobe and ramp up down effects Mode 2 6 Channel 1 Master dimmer 2 Red 3 Green 4 Blue 5 White 6 Shutter DMX Mode 3 5 Channel 5 Channel...

Страница 32: ...P7 User Manual Rev A DMX Mode 5 RGB RGB Mode provides RGB color mixing Mode 5 RGB 1 Red 2 Green 3 Blue DMX Mode 6 Easy Easy Mode provides a virtual color wheel effect and a Master dimmer Mode 6 Easy 1 Color wheel 2 Master dimmer ...

Страница 33: ...lue 91 95 35 7 37 3 LEE 116 Medium Blue Green 96 100 37 6 39 2 LEE 124 Dark Green 101 105 39 6 41 2 LEE 139 Primary Green 106 110 41 6 43 1 LEE 089 Moss Green 111 115 43 5 45 1 LEE 122 Fern Green 116 120 45 5 47 1 LEE 738 JAS Green 121 125 47 5 49 0 LEE 088 Lime Green 126 130 49 4 51 0 LEE 100 Spring Yellow 131 135 51 4 52 9 LEE 104 Deep Amber 136 140 53 3 54 9 LEE 179 Chrome Orange 141 145 55 3 5...

Страница 34: ...00 0 Fade 6 Shutter Shutter closed 0 15 0 5 9 0 Snap Random strobe 16 47 6 3 18 4 Ramp up slow fast 48 79 18 8 31 0 Ramp down slow fast 80 111 31 4 43 5 Ramp up down slow fast 112 143 43 9 56 1 Strobe pause 5s 1s slow fast 144 199 56 5 78 0 Strobe 1Hz 20 Hz slow fast 200 239 78 4 93 7 Shutter open 240 255 94 1 100 7 Dimmer Master intensity 0 100 0 255 0 100 0 Fade 8 CTO Color temperature cool warm...

Страница 35: ... Hz slow fast 200 239 78 4 93 7 Shutter open 240 255 94 1 100 DMX Mode 3 5 Channel 5 DMX Channels Channel Command DMX range Percent Default DMX Fade 1 Dimmer Master intensity 0 100 0 255 0 100 0 Fade 2 Red Intensity 0 100 0 255 0 100 0 Fade 3 Green Intensity 0 100 0 255 0 100 0 Fade 4 Blue Intensity 0 100 0 255 0 100 0 Fade 5 White Intensity 0 100 0 255 0 100 0 Fade DMX Mode 4 RGBW 4 DMX Channels ...

Страница 36: ... 100 37 6 39 2 LEE 124 Dark Green 101 105 39 6 41 2 LEE 139 Primary Green 106 110 41 6 43 1 LEE 089 Moss Green 111 115 43 5 45 1 LEE 122 Fern Green 116 120 45 5 47 1 LEE 738 JAS Green 121 125 47 5 49 0 LEE 088 Lime Green 126 130 49 4 51 0 LEE 100 Spring Yellow 131 135 51 4 52 9 LEE 104 Deep Amber 136 140 53 3 54 9 LEE 179 Chrome Orange 141 145 55 3 56 9 LEE 105 Orange 146 150 57 3 58 8 LEE 021 Gol...

Страница 37: ...200 K 4200 K 5600 K 7200 K 8000 K High resolution dimmer 0 100 continuous Strobe Variable speed max 20 Hz Pre programmed regular and random strobe and pulse effects Control Control system USITT DMX512 Onboard interface Control panel with backlit LCD graphical display Installation Orientation Any Ingress protection rating IP65 Location Indoors or temporary outdoor location Floorstand mounting brack...

Страница 38: ...ncluded items Floorstand Installation Bracket Power cable depending on region US power cable 16 A 14 AWG UL listed E304117 SJT 4 9 ft EU power cable 16 A 1 5mm H07RN F 1 5 m Shipping options Single product Cardboard box Tour packs are available please ask your GLP supplier for details Dimensions and weight Depth 175 mm 6 9 ins Width 254 mm 10 0 ins Height 210 mm 8 3 ins Height including bracket 28...