49
Model: GGF-400, GGF-720
Fryer Operation
5.1.10
Controller Errors & Alarms
Continued on Next Page
ERROR CODE DESCRIPTION
(Upper Display)
PROBLEM
OPEN
DRAIN IS OPEN
Drain valve is open, or not completely closed. Basket will be
raised, if down. Close drain to clear error.
----
CHECK OIL LEVEL, ENSURE VAT IS
FULL, IF FULL THEN PRESS
[START]
This is a secondary error displayed after closing drain clears the
OPEN error; confirmation of oil level.
ER03
LOW OIL LEVEL – ENSURE VAT IS
FULL (Element/Add Level
Differential Warning)
The oil level is below the
[ADD]
line in the vat. Add oil to the
[FULL]
level mark & stir. Error will remain in effect until probe
temp differential is resolved.
ER06
LOW OIL LEVEL – ENSURE VAT IS
FULL – PRESS [START]
(Post ER03 Warning)
After an
ER03
is cleared, this is displayed until user presses
[START]
to confirm oil level.
ER07
MAX ELEMENT TEMP – PRESS
[START] (Post Warning)
Error is displayed after
MAX
element temperature
(ER19)
has
occurred and element has cooled below
MAX
temperature, .
ER13
OIL PROBE Error
Problem with the
variable oil temp probe
.
Service technician
generally required.
ER15
ELEMENT PROBE Error
Problem with
element temp probe
, attached directly to heating
element.
Service technician generally required.
ER17
ADD LEVEL PROBE Error
Problem with
add level probe
at vat
[ADD]
mark. Fryer without
this probe should have
ELMT-ADD DIFF ENABL
E setting
[OFF]
in
Factory Settings
.
Probe cannot be bypassed
.
Service technician
generally required.
ER19
MAX ELEMENT TEMP Error
The maximum heating element temperature has been exceeded.
This is a safety device; NEVER bypass this Probe
.
ER25
GUARD BAND EXCEEDED
Actual oil temperature deviates from setpoint by the Guard Band
amount. Allow oil to cool, or heat, to within range. Factory
ER37
EEPROM Error
An error occurred while saving settings to the EEPROM.
Contact
Giles Tech Service (800.554.4537).
ER38
Internal ADC Error
The ADC (Analog-to-Digital Converter) chip has stopped working.
MCB1 board must be replaced.
Contact Giles Tech Service
(800.554.4537).
Conditions which can cause unsafe operation or damage to the unit
(open valves,
low oil level, high temp, hood problems, etc.)
will halt operation, activate an alarm
tone and display error codes/messages. Error Codes are
shown on the
Lower 7-Segment Display
; error messages and
prompts are shown on the
Upper OLED Display
. Generally,
heating elements are disabled until error condition has been
corrected. Pressing the
[ALARM]
key silences the alarm tone,
but does not clear error. Error Codes are shown in the Table
below and further details are discussed in the following section.
OLED
7-Segment
ALARM
Содержание GGF Series
Страница 13: ...4 Model GGF 400 GGF 720 Introduction ...
Страница 26: ...Model GGF 400 GGF 720 Overview 18 3 1 Control Panel 5 6 4 3 2 1 7 ...
Страница 28: ...20 Model GGF 400 GGF 720 Overview 3 2 Lower Cabinet 5 6 4 3 2 1 7 ...
Страница 32: ...24 Model GGF 400 GGF 720 Overview 3 4 Basket and Elevator Assembly 3 1 2 4 ...
Страница 38: ...30 Model GGF 400 GGF 720 Overview Notes ...
Страница 42: ...34 Fryer Preparation Model GGF 400 GGF 720 ...
Страница 80: ...72 Troubleshooting Model GGF 400 GGF 720 ...
Страница 84: ...76 Parts List Not shown 8 3 Front Lower Cabinet Model GGF 400 GGF 720 2 3 4 1 5 6 7 8 9 10 12 13 11 ...
Страница 86: ...78 Parts List 8 4 Rear Cabinet 2 4 1 5 9 3 6 10 11 7 8 12 Model GGF 400 GGF 720 13 14 15 16 17 18 19 ...
Страница 88: ...80 Parts List 8 5 Plumbing Model GGF 400 GGF 720 1 2 2 3 3 4 5 6 7 7 7 7 8 10 11 9 12 ...
Страница 90: ...82 Parts List 8 6 Basket Basket Cover Model GGF 400 GGF 720 1 2 3 ...
Страница 92: ...84 Parts List 8 7 Filter Pan Accessory Purchased Separately Model GGF 400 GGF 720 1 2 3 6 5 4 8 10 7 9 11 12 ...
Страница 94: ...86 Parts List Notes Model GGF 400 GGF 720 ...
Страница 95: ......