LFP
This command locks, unlocks, or returns the current state of the front panel from the serial port.
O
[DEVICE]
LFP
<X>
Explanation
<X>
X=0
Parameter to unlock the front panel.
X=1
Parameter to lock the front panel
X=2
Parameter to toggle the state from one state to the other (regardless of current state)
X=Null
Parameter to return the current state of the front panel
Return Values
The command will return the updated condition of the front panel.
LMO
This command changes or reports back the setting of the last microphone on mode for each AP400.
O
[DEVICE]
LMO
<X>
Explanation
<X>
X=0
Parameter to set the mode to OFF
X=1
Parameter to set the mode to Microphone #1
X=2
Parameter to set the mode to Last Microphone On
X=Null
Parameter to return the current mode
Return Values
The command will return the updated mode for the selected AP400 in the same format as the command.
LVL
This command reports back the level for a given channel.
O
[DEVICE]
LVL
<CH> <W>
Explanation
<CH>
CH= 1-4
Parameter to apply to the specified channel
CH= A-D,T
Parameter to apply to the specified channel
<W>
W= I
Parameter to specify an input meter
W= O
Parameter to specify an output meter
W= A
Parameter to specify an adaptive ambient meter (channels 1-4 only)
Return Values
The command will return the input level of the channel in the same format as the command.
A P P E N D I C E S •
APPENDIX F: SERIAL PORT COMMANDS
T E CH N I C A L S U P P O RT:
1.800.283.5936 (USA) OR 1.801.975.3760
65