A P P E N D I C E S •
APPENDIX F: SERIAL PORT COMMANDS
T E CH N I C A L S U P P O RT:
1.800.283.5936 (USA) OR 1.801.975.3760
61
EQ
This command changes or reports back the state of the equalizer for a microphone
O
[DEVICE]
EQ
<CH> <X>
Explanation
<CH>
CH= 1-4
Parameter to apply to the specified micrphone channel
CH= *
Parameter to apply command to all micrphone channels
<X>
X=0
Parameter to set the state to OFF
X=1
Parameter to set the state to ON
X=2
Parameter to toggle the state from one state to the other (regardless of current state)
X=Null
Parameter to return the current state
Return Values
The command will return the updated condition (On=1, Off=0) of the equalizer in the same format as the command.
FLOW
This command selects or reports whether hardware flow control is enable or disabled for the AP400. Hardware flow control is
implemented using RTS and CTS.
O
[DEVICE]
FLOW
<X>
Explanation
<X>
X=0
Sets flow control to OFF
X=1
Sets flow control to ON
X=Null
Parameter to return the current mode
Return Values
The command will return the updated condition (On=1, Off=0) of the AP400 in the same format as the command.
FMP
This command selects or returns the current status of the first microphone priority mode for the AP400.
O
[DEVICE]
FMP
<X>
Explanation
<X>
X=0
Parameter to select first microphone priority mode to OFF
X=1
Parameter to select first microphone priority mode to ON
X=Null
Parameter to return the current mode
Return Values
The command will return the updated condition (On=1, Off=0) of first mic priority mode in the same format as the command.
FPP
This command sets and reports the current passcode setting for the AP400.
O
[DEVICE]
FPP
<XXXXX>
Explanation
<XXXXX>
X=1
▲
button
X=2
ENTER button
X=3
ESC button