4.
Output 1–4. This is an additional bank of Phoenix™ block connec-
tors. These outputs are configured at the factory to be direct outputs of
the four mic inputs, but may be configured to contain a mix of any indi-
vidual mic or line-level inputs. Nominal output is 0dBm. For electrical
specifications, see Specifications, Page 43.
5.
Mic 1–4 This bank of Phoenix™ block connectors is for connection
of up to four mic/line-level inputs (selectable) with the three-terminal
Phoenix™ push-on connector(s).
6.
G-Link In. This RJ45 connector is part of the AP400 RS485 local area
network (LAN). The first Gentner unit in the G-Link network must be ter-
minated in the G-LINK IN connector with a G-Link terminator. The first
Gentner unit’s G-LINK OUT connector is then attached to the G-LINK IN
connector on the next Gentner unit, forming a daisy-chain network.
7.
G-Link Out. This RJ45 connector is part of the AP400 RS485 LAN.
The last Gentner unit in the G-Link network must have the G-LINK OUT
connector terminated with a G-Link terminator. The first Gentner unit’s
G-LINK OUT connector is attached to the G-LINK IN connector on the
next Gentner unit, forming a daisy-chain network.
8.
RS232. This female DB9 serial port is for interconnection between
the AP400 and a PC, modem, or other custom remote control. For serial
communications protocol, see Appendix F, Page 54.
9.
Control/Status. This female DB25 connector is used to interface par-
allel control to the AP400. Most of the pins on this connector can be
programmed to perform any function via a closure to ground. For
instructions on how to program the control and status pins, see page
71-72. The default settings allow control and status of the front panel,
mics, outputs, volume, presets and inputs. These pins go low when
active. The six presets can be activated at any time via these connec-
tors. For pinouts, including a description of the default settings, see
Appendix C, page 49.
10.
Speaker. One 5W, 4-16 ohm speaker can be directly connected to
the AP400, eliminating the need for a power amplifier.
11.
Telco Line. Connects to your telephone line source.
12.
Telco Set. Connects to your telephone handset.