6. & 7. G-Link Connections
will be discussed on page 20.
8. RS232
. Connect the RS232 port (right) to a free COM port of a PC
or to a custom remote controller. The AP400’s baud rate as shipped
from the factory is 9,600 (bps) baud. However, if your application
requires a different baud rate (19,200 or 38,400), refer to Baud Rate,
page 32, to change this setting. For serial communications protocol,
see Appendix F, page 54.
9. Control/Status:
Connect the DB25 CONTROL/STATUS port (right)
to any device you wish to use for parallel control or status indication.
10. Speaker.
Connect the speaker wire to the + (red) and - (black)
binding post connectors (right). One 5 W, 4-16 Ohm speaker can be
directly connected to the AP400, eliminating the need for an external
power amplifier.
11. Telco Line.
Plug your telephone line from the source into the
RJ11C LINE jack (right).
12. Telco Set
. Plug your telephone set into the RJ11C SET jack
(right).
If you are installing only one AP400 and you are not connecting it to any
other AP products, you have completed installation. The units are pre-
programmed at the factory; no other adjustments are required unless
you want to customize the system. You may skip to
Chapter 4—
Operation
, beginning on page 40.
If you want to customize the set up, refer to the section on
LCD
Programming
beginning on page 23.
If you are connecting additional Audio Perfect™ units in your system,
continue with Step 2 on the next page.