Operating Envelope Indicator Lights
The operating envelope indicator lights will come
on to notify the operator that a function has been
interrupted and/or an action is required by the
operator.
Lower Primary Boom indicator
light flashing: Lower the primary
boom until the indicator light is
off.
Machine Not Level indicator
light flashing: The tilt alarm will
be sounding when this light is
flashing. Move the machine to a
firm, level surface.
Platform Not Level indicator light
flashing: The tilt alarm will be
sounding when this light is
flashing. The Platform Level
toggle switch will only work in
the direction that will level the
platform. Level the platform until
the indicator light is off.
Platform Level Recovery
1
Press down the foot switch.
2
Push and hold the platform level recovery
switch up.
3
Move the platform level switch in the desired
direction.
Note: The platform level switch will only work in the
direction that will return the platform to a level
position.
Note: From +/-10 degrees of platform level up to
+/-14.9 degrees the platform can still be recovered
from the ground controls or by using the platform
level recovery toggle switch in the procedure
above. Once the platform level reaches
+/-15 degrees the only way to recover is to use the
Service/Recovery key switch on the side of the
ground controls to activate Recovery Mode.
Platform Out of Level (P22 code)
Bypass key position to be used to level the
platform if ground control display shows platform
out of level (P22) and platform level controls do not
work.
To operate:
1
Turn the engine off.
2
Turn the main key switch to ground control.
Remove the key from the main key switch and
insert the key into the bypass/recovery key
switch.
3
Turn the bypass/recovery
key switch to the bypass
position.
4
Using emergency power, operate the platform
level button to level the platform.
5
Turn the bypass/recovery key switch to the run
position.
6
Remove the key from the bypass/recovery key
switch and insert the key into the main key
switch.
7
Push in and then pull out the red Emergency
Stop button.
8
If the P22 code is still visible, tag and remove
the machine from service until the fault has
been corrected by a qualified service
technician.
Platform Out of Level
(Platform Level > 15 Degrees Fault)
If ground control display shows PLATFORM
LEVEL > 15 DEGREES FAULT and the platform
level controls do not work, the machine will need to
be recovered by trained and authorized personnel
or a qualified service technician.
P22
P22
Содержание Z-80/60
Страница 8: ...Operator s Manual Sixth Edition Sixth Printing Personal Safety 6 Z 80 60 Part No 226482...
Страница 10: ...Operator s Manual Sixth Edition Sixth Printing Personal Safety 8 Z 80 60 Part No 226482...
Страница 43: ...Sixth Edition Sixth Printing Operator s Manual Inspections Part No 226482 Z 80 60 41...
Страница 65: ...Distributed By www genielift com...